Telemedicine Home Blood Pressure Measurements and Progression of Albuminuria in Elderly People With Diabetes

Author:

Palmas Walter1,Pickering Thomas G.1,Teresi Jeanne1,Schwartz Joseph E.1,Field Lesley1,Weinstock Ruth S.1,Shea Steven1

Affiliation:

1. From the Department of Medicine (W.P., L.F., S.S.), Behavioral Cardiovascular Health and Hypertension Program (T.G.P.), Department of Epidemiology, Joseph Mailman School of Public Health (S.S.), and Department of Biomedical Informatics (S.S.), Columbia University, New York; Research Division (J.T.), Hebrew Home for the Aged at Riverdale, Bronx; Columbia University Stroud Center and Faculty of Medicine (J.T.), New York State Psychiatric Institute, New York; Department of Psychiatry and Behavioral...

Abstract

We assessed whether home blood pressure monitoring improved the prediction of progression of albuminuria when added to office measurements and compared it with ambulatory blood pressure monitoring in a multiethnic cohort of older people (n=392) with diabetes mellitus, without macroalbuminuria, participating in the telemedicine arm of the Informatics for Diabetes Education and Telemedicine Study. Albuminuria was assessed by measuring the spot urine albumin:creatinine ratio at baseline and annually for 3 years. The ambulatory sleep:wake systolic blood pressure ratio was categorized as dipping (ratio: ≤0.9), nondipping (ratio: >0.9 to 1.0), and nocturnal rise (ratio: >1.0). In a repeated-measures mixed linear model, after adjustment that included office pulse pressure, home pulse pressure was independently associated with a higher follow-up albumin:creatinine ratio ( P =0.001). That association persisted ( P =0.01) after adjusting for 24-hour pulse pressure and nocturnal rise, which were also independent predictors ( P =0.02 and P =0.03, respectively). Cox proportional hazards models examined the progression of albuminuria (n=74) as defined by cutoff values used by clinicians. After the adjustment for office pulse pressure, the hazards ratio (95% CI) per 10-mm Hg increment of home pulse pressure was 1.34 (range: 1.1 to 1.7; P =0.01). Home pulse pressure was not an independent predictor in the model including ambulatory monitoring data; a nocturnal rise was the only independent predictor ( P =0.035). Cox models built separately for home pulse pressure and ambulatory monitoring exhibited similar calibration and discrimination. In conclusion, nocturnal blood pressure elevation was the strongest predictor of worsening albuminuria. Home blood pressure measurements added to office measurements and may constitute an adequate substitute for ambulatory monitoring.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3