Quantification of absolute luminal diameter by computer-analyzed digital subtraction angiography: an assessment in human coronary arteries.

Author:

Rosenberg M C1,Klein L W1,Agarwal J B1,Stets G1,Hermann G A1,Helfant R H1

Affiliation:

1. Philadelphia Heart Institute, Presbyterian-University of Pennsylvania Medical Center 19104.

Abstract

Determination of absolute lumen diameters has been shown to be useful in predicting the functional importance of a coronary stenosis. In this study, both single-plane and orthogonal biplane digital subtraction angiograms were obtained in human cadaver coronary arteries. A single absolute diameter was calculated at the site of greatest narrowing in 20 segments by two automated computerized algorithms. Minimum and maximum diameters at the site of the stenosis were measured from pathologic sections prepared after pressure fixation. Method 1, which determines the edges by means of the first derivative of the videodensity curve, derived absolute diameters that fell between the pathologic minimum and maximum in 10 of 20 segments. Method 2, which determines the edges by an average of the first and second derivatives of the videodensity change, derived absolute diameters that fell between the pathologic minimum and maximum diameters in 15 of 20 segments. Method 1 correlated well with the maximum pathologic diameter (r = .76) and less well with the minrmum pathologic diameter (r = .67). Method 2 correlated very well with the maximum pathologic diameter (r = .79) and also correlated well with the minimum pathologic diameter (r = .74). As would be expected, the computerized algorithms tended to overestimate the minimum pathologic diameter and to underestimate the maximum pathologic diameter. In six segments, two orthogonal views were analyzed; no further accuracy was discernible over single-plane determinations. Thus quantitative coronary angiography by digital subtraction angiography is sufficiently accurate to be of use in the measurement of the severity of a coronary stenosis.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 24 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Impact of two formulas to calculate percentage diameter stenosis of coronary lesions: from stenosis models (phantom lesion model) to actual clinical lesions;The International Journal of Cardiovascular Imaging;2019-07-27

2. Perspective on CFD studies of coronary artery disease lesions and hemodynamics: A review;International Journal for Numerical Methods in Biomedical Engineering;2014-01-23

3. Accuracy of Stress Echocardiography;Stress Echocardiography;2003

4. Angiokardiographie;Technik in der Kardiologie;2002

5. Issues in the performance of quantitative coronary angiography in clinical research trials;What’s New in Cardiovascular Imaging?;1998