Single-chamber cardiac pacing with activity-initiated chronotropic response: evaluation by cardiopulmonary exercise testing.

Author:

Benditt D G,Mianulli M,Fetter J,Benson D W,Dunnigan A,Molina E,Gornick C C,Almquist A

Abstract

In this study, sequential cardiopulmonary exercise testing was used to assess the physiologic benefits of a single-chamber ventricular pacing system that utilizes a piezoceramic sensor to adjust heart rate by detecting "physical activity." An initial exercise test was conducted with the pacemaker programmed (based on a randomization table) to either the fixed rate (VVI, 70 beats/min) or rate-variable (VVI-Act) mode, and the results were compared with those obtained during a second exercise test in which the pacemaker was programmed to the alternate pacing mode. A 1.5 to 2 hr rest period was permitted between exercise tests, each of which consisted of a symptom-limited constant speed (3.0 mph) Balke protocol with 2 min stages commencing at 0.0% grade with increments of 2.5% at end of each stage. Compared with findings during fixed-rate VVI pacing, VVI-Act pacing was associated with greater exercise-induced positive chronotropic response (mean maximum heart rate VVI-Act 128 +/- 15.3 beats/min vs VVI 90 +/- 28.4 beats/min; p less than .01), prolongation of exercise duration (VVI-Act 10.2 +/- 3.8 min vs VVI 7.7 +/- 2.5 min; p less than .01), increased peak oxygen consumption (VVI-Act 1617 +/- 656 ml O2/min vs VVI 1325 +/- 451 ml O2/min; p less than .01), and onset of anaerobic threshold at a higher oxygen consumption (VVI-Act 1208 +/- 343 ml O2/min vs VVI 1064 +/- 377 ml O2/min: p less than .01). Additionally, of 44 comparable exercise stages tested in the two pacing modes, perceived exertion (assessed by a numerical grading system) was lower in 38 of 44 instances during VVI-Act compared with VVI pacing.(ABSTRACT TRUNCATED AT 250 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference35 articles.

1. Physiological Cardiac Pacing

2. Newer modes of cardiac pacing. Part II. Intraoperative evaluation and selection of pacemaker for bradyarrhythmias;Furman S;Mod Concepts Cardiovasc Dis,1983

3. Rate responsive pacing;Rickards AF;Clin Prog Electrophysiol Pacing,1983

4. Chronotropic incompetence in exercise testing

5. Atrial Flutter, Atrial Fibrillation, and Other Primary Atrial Tachycardias

Cited by 120 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3