Demonstration of a widely distributed atrial pacemaker complex in the human heart.

Author:

Boineau J P1,Canavan T E1,Schuessler R B1,Cain M E1,Corr P B1,Cox J L1

Affiliation:

1. Division of Cardiothoracic Surgery, Washington University School of Medicine, St. Louis, MO 63110.

Abstract

Atrial depolarization was analyzed in 14 patients with the Wolff-Parkinson-White syndrome undergoing surgery to ablate accessory atrioventricular pathways associated with tachyarrhythmias. Bipolar potentials were recorded simultaneously from 156 atrial epicardial electrodes arranged in three templates to fit the anterior and posterior aspects of both atria. Spontaneous or sinus rhythms were recorded, as were atrial escape rhythms after overdrive pacing at rates of 150 and 200 beats/min. Atrial activation maps revealed different patterns of impulse initiation varying from typical unifocal sinus node impulse origin, unifocal extranodal impulse origin, and multicentric impulse origin from two to four widely distributed atrial pacemaker sites. In subjects demonstrating only unifocal impulse origin during control or sinus rhythm, other widely divergent pacemaker sites were recorded in other maps during subsequent rhythms. In addition to sites located at the upper superior vena cava-right atrium junction, pacemakers also dominated at sites anterior and inferior to the sinus node region during both control and escape depolarizations. Most of the subjects were found to have two or more pacemaker sites when maps of all control and postpacing conditions were analyzed. The right atrial pacemaker region encompassed a zone of 7.5 X 1.5 cm centered about the long axis of the sulcus terminalis posteriorly and the precaval band anteriorly. An unexpected finding was the participation of left atrial escape pacemakers. The functional behavior of both the control and escape pacemakers, as assessed by sinus node recovery time, was normal, indicating physiologic operation of the extranodal sites as part of an overall system of distributed pacemakers involved in the control of rate. Although functional assessment was limited in these initial patient studies, correspondence with similar observations in extensive previous canine studies supports the concept of a widely distributed atrial pacemaker complex in man.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3