The effect of contractility and preload on matching between the canine left ventricle and afterload.

Author:

Myhre E S,Johansen A,Bjørnstad J,Piene H

Abstract

We define matching between ventricle and afterload to imply that the ventricle is adapted to its afterload to yield maximum external work output. For the ventricle, this optimal adaption will depend on end-diastolic dimension, heart rate, and contractility. Because contractility is impaired during ventricular failure, we propose that the adaption between ventricle and load is not as good during failure as during normal conditions. According to our definition, this implies that during failure external work output is less than maximum. Ventricle-load matching is then not present, i.e., a mismatch exists between ventricle and load. This hypothesis was tested in a canine preparation in which arterial load of the left ventricle was varied from one beat to the next. Left ventricular depression was induced by injections of 50 micron microspheres into the left coronary bed. We observed left ventricular stroke volume and external work during afterload variations at three different preload levels before and after microembolization. Before embolization the control observations of work and stroke volume were positioned at the apex of parabolas relating work to stroke volume. After embolization, however, control observations fell down along the left limb of the parabolas. These observations were independent of preload. Thus this study, carried out in a preparation with the heart in situ, supports the idea that the normal left ventricle is matched to its load and demonstrates ventricle-load mismatch when the left ventricle is failing.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference34 articles.

1. Afterload mismatch and preload reserve: A conceptual framework for the analysis of ventricular function

2. Effects of Alterations in Aortic Impedance on the Performance of the Ventricles

3. Flow and power output of right ventricle facing load with variable input impedance;Piene H;Am J Physiol,1979

4. Does normal pulmonary impedance constitute the optimum load for the right ventricle?;Piene H;Am J Physiol,1982

Cited by 40 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3