Diagnostic Performance of a Smartphone‐Based Photoplethysmographic Application for Atrial Fibrillation Screening in a Primary Care Setting

Author:

Chan Pak‐Hei1,Wong Chun‐Ka1,Poh Yukkee C.2,Pun Louise3,Leung Wangie Wan‐Chiu3,Wong Yu‐Fai3,Wong Michelle Man‐Ying3,Poh Ming‐Zher2,Chu Daniel Wai‐Sing3,Siu Chung‐Wah1

Affiliation:

1. Cardiology Division, Department of Medicine, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China

2. Cardiio Inc., Cambridge, MA

3. Department of Family Medicine and Primary Healthcare, Hong Kong East Cluster, Hong Kong, China

Abstract

Background Diagnosing atrial fibrillation ( AF ) before ischemic stroke occurs is a priority for stroke prevention in AF . Smartphone camera–based photoplethysmographic ( PPG ) pulse waveform measurement discriminates between different heart rhythms, but its ability to diagnose AF in real‐world situations has not been adequately investigated. We sought to assess the diagnostic performance of a standalone smartphone PPG application, Cardiio Rhythm, for AF screening in primary care setting. Methods and Results Patients with hypertension, with diabetes mellitus, and/or aged ≥65 years were recruited. A single‐lead ECG was recorded by using the AliveCor heart monitor with tracings reviewed subsequently by 2 cardiologists to provide the reference standard. PPG measurements were performed by using the Cardiio Rhythm smartphone application. AF was diagnosed in 28 (2.76%) of 1013 participants. The diagnostic sensitivity of the Cardiio Rhythm for AF detection was 92.9% (95% CI ] 77–99%) and was higher than that of the AliveCor automated algorithm (71.4% [95% CI 51–87%]). The specificities of Cardiio Rhythm and the AliveCor automated algorithm were comparable (97.7% [95% CI : 97–99%] versus 99.4% [95% CI 99–100%]). The positive predictive value of the Cardiio Rhythm was lower than that of the AliveCor automated algorithm (53.1% [95% CI 38–67%] versus 76.9% [95% CI 56–91%]); both had a very high negative predictive value (99.8% [95% CI 99–100%] versus 99.2% [95% CI 98–100%]). Conclusions The Cardiio Rhythm smartphone PPG application provides an accurate and reliable means to detect AF in patients at risk of developing AF and has the potential to enable population‐based screening for AF .

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine

Cited by 192 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3