Angiographic validation of eigenvolume to measure left ventricular size.

Author:

Chagas A C1,Glantz S A1

Affiliation:

1. Cardiovascular Research Institute, University of California, San Francisco, CA 94143.

Abstract

Radiopaque markers implanted in the left ventricle allow one to follow the motion of specific elements of myocardium and compute a measure of relative left ventricular volume, called "eigenvolume." Workers in our laboratory partially validated this measure in excised dog hearts by comparing eigenvolumes with volumes of balloons in the left ventricle. Perhaps because the balloon did not fully fill the left ventricle, there was a significant nonzero intercept in the relation between eigenvolume and balloon volume. Therefore, the results only partially confirmed the eigenvolume theory because eigenvolume should be proportional to cavity volume. This study compares eigenvolume with left ventricular volume measured by biplane angiography in intact beating hearts following hemodynamic interventions (atropine, phenylephrine, nitroprusside, volume loading, and propranolol). We performed 32 angiograms in five dogs. A high correlation (r = 0.958 +/- 0.029 [SD]) was found between eigenvolumes and left ventricular volumes. In contrast to earlier in vitro validations and consistent with theory, the intercept of the relation between eigenvolume and left ventricular cavity volume (angiovolume) was not significantly different from zero. These data strengthen the hypothesis that eigenvolume accurately reflects true left ventricular volume in vivo. These same data were used to assess the immediate (i.e., within a few beats) effect of angiography. Left ventricular volume loading associated with the angiogram modestly (6%) increases left ventricular end-diastolic and end-systolic eigenvolumes without changing stroke volume or pressures, consistent with a mild negative inotropic effect.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Reference23 articles.

1. Permanent implantation of endocardia! tantalum screws: A new technique for functional studies of the heart in the experimental animal;Carlsson E;J Can Assoc Radial,1967

2. Measurement of left ventricular dimensions from implanted radiopaque markers.

3. Grover M Glantz SA: Endocardial pacing site affects left ventricular end-diastolic volume and performance in the intact anesthetized dog. Circ Res 1983-3:72-85

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3