Comparison of Clinical and Angiographic Outcomes After Saphenous Vein Graft Angioplasty Using Coronary Versus ‘Biliary’ Tubular Slotted Stents

Author:

Wong S. Chiu1,Popma Jeffrey J.1,Pichard Augusto D.1,Kent Kenneth M.1,Satler Lowell F.1,Mintz Gary S.1,Chuang Ya Chien1,Hong Mun K.1,Ditrano Christine J.1,Leon Martin B.1

Affiliation:

1. From the Department of Internal Medicine (Division of Cardiology) of the Washington Hospital Center, Washington, DC.

Abstract

Background Saphenous vein graft (SVG) angioplasty using 15-mm articulated, tubular slotted stents results in low (0% to 20%) residual diameter stenoses and infrequent (<5%) major complications. A “biliary” stent design with greater radial compressive strength, enhanced visibility, and more variable sizing (diameter and length) has been approved for noncoronary indications. A comparison of outcomes after coronary versus biliary stent placement in SVG stenoses has not been performed. The purpose of this study was to compare the angiographic and clinical results after SVG angioplasty using these two balloon-expandable, tubular slotted stent designs. Methods and Results During a 3-year period, 231 patients with 305 SVG lesions were treated using Palmaz-Schatz coronary (n=108) or biliary (n=123) stents. Cineangiograms were reviewed using qualitative morphological and quantitative angiographic methods. Time-dependent clinical outcome (freedom from death, Q-wave myocardial infarction, or the need for repeat coronary bypass surgery or SVG angioplasty) was assessed using Kaplan-Meier life-table methods. Unstable angina ( P <.001) and recent myocardial infarction ( P =.001) were present more often in patients undergoing biliary stent versus coronary stent placement. Biliary stent–treated SVG lesions were more frequently de novo ( P =.001), ostial in location ( P =.002), ≥10 mm in length ( P =.009), thrombus containing ( P =.001), and ulcerated ( P <.001) than coronary stent–treated SVG lesions. Angiographically, biliary stent–treated lesions had larger reference vessel diameter (3.43±0.59 mm versus 3.10±0.64 mm, P <.001), higher balloon-to-artery ratio (1.15±0.16 mm versus 1.07±0.19, P =.0001), and lower residual diameter stenosis (6±17% versus 14±11% in coronary stent–treated patients; P <.001). Procedural success rates were high (95%), in-hospital major complications were uncommon (<3%), and follow-up clinical outcomes were favorable (6-month event-free survival ≈80%) in both groups. Conclusions Despite frequent short-term ischemic syndromes and unfavorable lesion characteristics, both biliary and coronary cohorts have similarly favorable short-term procedural results and long-term clinical outcomes. The increased strut thickness of the biliary stent confers greater fluoroscopic visibility and radial compressive strength in exchange for decreased stent flexibility and added technical demand in stent deployment. Extreme caution is recommended with biliary stent placement in the treatment of SVG lesions as clinical results are highly operator dependent.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 45 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3