Reduction in Thrombotic Events With Heparin-Coated Palmaz-Schatz Stents in Normal Porcine Coronary Arteries

Author:

Hårdhammar Peter A.1,van Beusekom Heleen M.M.1,Emanuelsson Håkan U.1,Hofma Sjoerd H.1,Albertsson Per A.1,Verdouw Pieter D.1,Boersma Eric1,Serruys Patrick W.1,van der Giessen Willem J.1

Affiliation:

1. From the Department of Cardiology, Thoraxcenter, Erasmus University Rotterdam (The Netherlands), and Division of Cardiology, Sahlgrenska Hospital, Gothenburg, Sweden.

Abstract

Background The use of stents improves the result after balloon coronary angioplasty. Thrombogenicity of stents is, however, a concern. In the present study, we compared stents with an antithrombotic coating with regular stents. Methods and Results Regular stents were placed in coronary arteries of pigs receiving no aspirin (group 1; n=8) or aspirin over 4 weeks (group 2, n=10) or 12 weeks (group 3, n=9). Stents coated with heparin (antithrombin III uptake, 5 pmol/stent) were placed in 7 pigs that did not receive aspirin (group 4). The other animals received aspirin and coated stents with a heparin activity of 12 pmol antithrombin III/stent (group 5, n=10) or 20 pmol/stent (group 6, n=10; group 7, n=10). Quantitative arteriography was performed at implantation and after 4 (groups 1, 2, and 4 through 6) or 12 weeks (groups 3 and 7). In an additional 5 animals, five regular and five coated stents (20 pmol/stent) were placed and explanted after 5 days for examination of the early responses to the implants. Thrombotic occlusion of the regular stent occurred in 9 of 27 in groups 1 through 3. However, in 0 of 30 of the animals receiving high-activity heparin-coated stents (groups 5 through 7), thrombotic stent occlusion was observed ( P <.001). Histological analysis at 4 weeks showed that the neointima in group 6 was thicker compared with its control group 2 (259±104 and 117±36 μm, P <.01), but at 12 weeks the thickness was similar (152±61 and 198±49 μm, respectively). Comparison at 5 days suggested delayed endothelialization of the coating. Conclusions High-activity heparin coating of stents eliminates subacute thrombosis in porcine coronary arteries.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3