Myocardial Gd-DTPA Kinetics Determine MRI Contrast Enhancement and Reflect the Extent and Severity of Myocardial Injury After Acute Reperfused Infarction

Author:

Kim Raymond J.1,Chen Enn-Ling1,Lima Joa˜o A.C.1,Judd Robert M.1

Affiliation:

1. the Cardiology Division, Department of Medicine (R.J.K., J.A.C.L.), and the Division of Thoracic and Magnetic Resonance Imaging, Department of Radiology (R.M.J.), Johns Hopkins Hospital, Baltimore, Md, and the Department of Biophysics (E.-L.C.), University of Pennsylvania, Philadelphia.

Abstract

Background Contrast medium–enhanced magnetic resonance images of acute, reperfused infarcts have shown hypoenhanced and hyperenhanced regions in areas of injured myocardium. The precise mechanisms that lead to these altered enhancement patterns are unknown. This study was designed to evaluate possible mechanisms and to relate altered enhancement patterns to myocardial perfusion and viability. Methods and Results Thirteen rabbits underwent in situ coronary artery occlusion and reperfusion followed by isolated perfusion with cardioplegic solution. T1-weighted spin-echo images were acquired continuously during step changes in perfusate Gd-DTPA concentration. Regional blood flow was also measured by use of radioactive microspheres in all rabbits. There were marked differences in Gd-DTPA wash-in and washout time constants (wash-in, 0.8±0.1, 2.1±0.2, and 16.3±2.4 minutes, P <.001; washout, 1.6±0.1, 4.8±0.5, and 31.1±3.3 minutes, P <.001) in normal, infarct rim, and infarct core regions, respectively, resulting in differential enhancement of these regions. Microsphere flows in the infarct rim and core were 42.9±4.0% and 12.0±1.6% of normal myocardium and correlated well with washout time constants ( r =.86, y =0.77 x −0.002, P <.001), suggesting that these time constants index the severity of microvascular damage. In addition, spatial maps of washout time constants were produced. The extent of regions with abnormal time constants correlated well with triphenyltetrazolium chloride–determined infarct size ( r =.94, y =0.95 x +4.17, P <.001). Conclusions In contrast-enhanced magnetic resonance images of acute, reperfused rabbit infarcts, differential image intensity is primarily due to regional differences in contrast agent wash-in and washout time constants. These regional differences in time constants also indicate the extent and severity of myocardial injury.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 555 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3