Assessment of Transmural Distribution of Myocardial Perfusion With Contrast Echocardiography

Author:

Linka Andre Z.1,Sklenar Jiri1,Wei Kevin1,Jayaweera Ananda R.1,Skyba Danny M.1,Kaul Sanjiv1

Affiliation:

1. From the Cardiovascular Division, University of Virginia School of Medicine, Charlottesville, Va.

Abstract

Background —We hypothesized that by using our newly defined method of destroying microbubbles and measuring their rate of tissue replenishment, we could assess the transmural distribution of myocardial perfusion. Methods and Results —We studied 12 dogs before and after creation of left anterior descending coronary artery stenoses both at rest and during hyperemia (n=62 stages). Microbubbles were administered as a constant infusion, and myocardial contrast echocardiography (MCE) was performed with the use of different pulsing intervals. The video intensity versus pulsing interval plots derived from each myocardial pixel were fitted to an exponential function: y= A (1−e βt ), where A reflects microvascular cross-sectional area (or myocardial blood volume), and β reflects mean myocardial microbubble velocity. The product A · β represents myocardial blood flow (MBF). Average values for these parameters were derived from the endocardial and epicardial regions of interest placed over the left anterior descending coronary artery bed. Radiolabeled microsphere–derived MBF was also measured from the same regions. There was poor correlation between radiolabeled microsphere–derived MBF and A -endocardial/epicardial ratios (EER) ( r =0.46). The correlation with β -EER was better ( r =0.69, P <0.01). The best correlation with radiolabeled microsphere–derived MBF-EER was noted with A · β -EER ( r =0.88, P <0.01). Conclusions —The transmural distribution of myocardial perfusion can be accurately assessed with MCE with the use of our newly described method of tissue replenishment of microbubbles after their ultrasound-induced destruction. In the model studied, an uncoupling of the transmural distribution of MBF and myocardial blood volume was observed during reversal of the MBF-EER.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 123 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3