Affiliation:
1. From the Department of Cardiology (A.N., M.J.G., K.N.), Duke University Medical Center, and the Durham Veterans Administration Medical Center, Durham, NC; University of Michigan Medical Center (T.D.) (Ann Arbor); and University of Kentucky (A.N.) (Lexington).
Abstract
Background
The purpose of this investigation was to evaluate the outcome of pregnancy in women with implantable cardioverter-defibrillators (ICDs).
Methods and Results
A multicenter retrospective analysis was performed on women with an ICD who became pregnant. Data were collected on 44 patients. The mean age and ejection fraction at the time of the initial ICD implant were 25.6±4.9 years and 49.8±9.7%, respectively. The mean follow-up after the ICD implant was 4.8±2.8 years. Forty-two women had abdominally implanted generators, and 2 had a prepectoral device. Thirty had epicardial lead sensing systems, and 14 had transvenous. Thirty-six (82%) experienced no complications, and 8 (18%) had a medical or device-related complication. The ICD-related problems included tenderness at the ICD pocket scar (2 patients), generator migration (1), and pericarditis secondary to the epicardial patches (1). Medical complications were pulmonary embolism (1), therapeutic abortion (1), worsening hyperthyroidism (1), congestive heart failure (1), and weight loss (1). Thirty-seven women delivered vaginally, and 7 underwent cesarean section. Thirty-nine babies were born healthy, 1 was stillborn, 2 were small for gestational age, 1 had transient hypoglycemia, and 1 woman had a therapeutic abortion unrelated to the ICD. During pregnancy, 33 women received no ICD therapy, 8 had 1 shock, 1 had 5 discharges, 1 had 11 shocks, and 1 had 5 shocks. The total number of shocks during pregnancy ranged from 0 to 11, with an average of 0.66±1.9 discharges. Five women had 7 additional pregnancies without an ICD shock.
Conclusions
The mere presence of an ICD should not defer a women from becoming pregnant unless she has an underlying structural cardiac disease that is considered a contraindication. Pregnancy does not increase the risk of major ICD-related complications or result in a high number of ICD discharges.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Physiology (medical),Cardiology and Cardiovascular Medicine
Reference10 articles.
1. Davies GAL Herbert WNP. Cardiac disease in pregnancy. Cardiol Rev . 1995;3;5:262-272.
2. Cox JL Gardner MJ. Treatment of cardiac arrhythmias during pregnancy. Prog Cardiovasc Dis . 1993;2;36:137-178.
3. Pregnancy complicated by chronic cardiomyopathy and an automatic implantable cardioverter defibrillator
4. Isaacs JD Mulholland DH Hess LW Albert JR Martin RW. Pregnancy in a woman with an automatic implantable cardioverter defibrillator: a case report. J Reprod Med . 1993;36;6:487-488.
5. James DK Stirrat GM. Pregnancy and Risk: The Basis for Rational Management . New York NY: John Wiley & Sons; 1988.
Cited by
168 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献