Myocardial Protection by Brief Ischemia in Noncardiac Tissue

Author:

Gho Ben C.G.1,Schoemaker Regien G.1,van den Doel Mirella A.1,Duncker Dirk J.1,Verdouw Pieter D.1

Affiliation:

1. Experimental Cardiology, Thoraxcenter and Department of Pharmacology (Cardiovascular Research Institute COEUR), Erasmus University Rotterdam, Netherlands.

Abstract

Background Brief coronary artery occlusions (CAOs) protect both the artery's own perfusion territory (“myocardial preconditioning”) and adjacent “virgin” myocardium. Whether ischemia in remote organs protects myocardium is unknown. We examined whether brief occlusion of the anterior mesenteric artery (MAO) or left renal artery (RAO) protects against myocardial infarction. Methods and Results Area at risk (AR) and infarcted area (IA) were determined in anesthetized rats after 180 minutes of reperfusion following a 60-minute CAO. At normothermia (body temperature, 36.5°C to 37.5°C), IA/AR was 68±2% (mean±SEM, n=11) in control rats and 50±3% (n=9, P <.001) in rats preconditioned by 15-minute CAO 10 minutes before 60-minute CAO. A 15-minute MAO was equally protective (IA/AR=50±3%, n=10, P <.001), whereas 15-minute RAO failed to limit IA/AR (72±5%, n=8). Hypothermia (body temperature, 30°C to 31°C) did not affect IA/AR (67±3%, n=11) in control animals but enhanced protection by 15-minute CAO (IA/AR=22±3%, n=8), whereas protection by 15-minute MAO (IA/AR=44±5%, n=11, P <.001) was minimally enhanced. Hypothermia unmasked protection by 15-minute RAO (IA/AR=46±6%, n=9, P <.01). Hexamethonium (20 mg/kg IV) did not alter protection by 15-minute CAO, but it abolished protection by 15-minute MAO. When MAO was sustained throughout the study, cardioprotection was absent. Conclusions Brief ischemia in “remote” organs protects myocardium against infarction as effectively as myocardial preconditioning. The mechanism of protection by MAO differs from that of CAO, because ganglion blockade abolished protection by MAO but not by CAO. The neurogenic pathway is activated during reperfusion after 15-minute MAO, because sustained MAO failed to produce cardioprotection.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 514 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3