Disturbed Intracoronary Hemodynamics in Myocardial Bridging

Author:

Klues Heinrich G.1,Schwarz Ernst R.1,vom Dahl Jürgen1,Reffelmann Thorsten1,Reul Helmut1,Potthast K.1,Schmitz C.1,Minartz Jürgen1,Krebs Winfried1,Hanrath iPeter1

Affiliation:

1. From the Medical Clinic I, University Hospital, Rheinisch Westfälische Technische Hochschule, Aachen, and Helmholtz Institute for Biomedical Engineering (H.R., K.P., C.S.) Aachen, Germany.

Abstract

Background The purpose of this study was to evaluate the hemodynamic mechanisms leading to myocardial ischemia in patients with myocardial bridging. Myocardial bridging is known to induce angina and even severe myocardial ischemia. Methods and Results In 12 symptomatic patients with myocardial bridges, quantitative coronary angiography was performed to obtain systolic/diastolic vessel diameters within the bridged segments. Coronary flow velocities, flow reserve, and pressures were determined with a 0.014-in Doppler and a 0.014-in pressure microtransducer. In 3 symptomatic patients, coronary stents were implanted and hemodynamic measurements were repeated immediately and after 7 weeks. An in vitro validation of the pressure measurements was performed. Angiography revealed a systolic diameter reduction of 80.6±9.2% and a persistent diastolic reduction of 35.3±11% within the bridged segment. Diastolic flow velocities (cm/s) were increased (31.5±14.3 within versus 17.3±5.7 proximal and 15.2±6.3 distal, P <.001). Coronary flow reserve distal to the bridge was 2.5±0.5. There was an increased peak systolic pressure within the bridged segment (171±48 versus 113±10 mm Hg proximal, P <.001). Stent placement abolished the phasic lumen compression, the diastolic flow abnormalities, the intracoronary peak systolic pressure, and clinical symptoms. Coronary flow reserve improved to 3.8±0.3. Conclusions Coronary hemodynamics in myocardial bridges are characterized by a phasic systolic vessel compression with a localized peak pressure, persistent diastolic diameter reduction, increased blood flow velocities, retrograde flow, and a reduced flow reserve. These alterations may explain the occurrence of symptoms and ischemia in these patients. Intracoronary stent placement abolished all hemodynamic abnormalities and may improve clinical symptoms in otherwise unsuccessfully treated patients with myocardial bridges.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 171 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3