Imaging and Sizing of Atrial Septal Defects by Magnetic Resonance

Author:

Holmvang Godtfred1,Palacios Igor F.1,Vlahakes Gus J.1,Dinsmore Robert E.1,Miller Stephen W.1,Liberthson Richard R.1,Block Peter C.1,Ballen Barbara1,Brady Thomas J.1,Kantor Howard L.1

Affiliation:

1. From the Cardiac Unit (G.H., I.F.P., R.R.L., P.C.B., B.B., H.L.K.), the Department of Radiology (G.H., R.E.D., S.W.M., T.J.B.), and the Department of Surgery (G.J.V.), Massachusetts General Hospital and Harvard Medical School, Boston, Mass.

Abstract

BackgroundDevelopment of techniques for percutaneous closure of atrial septal defects (ASDs) makes accurate noninvasive sizing of ASDs important for appropriate patient selection.Methods and ResultsMagnetic resonance (MR) images of ASDs were obtained in 30 patients (mean age, 41±16 years) by both spin-echo and phase-contrast cine MR imaging. Spin-echo images were obtained in two orthogonal views (short-axis and four-chamber) perpendicular to the plane of the ASD. Spin-echo major and minor diameters were measured, and spin-echo defect area was calculated. Phase-contrast cine MR images were obtained in the plane of the ASD, and cine major diameter and defect area were measured from the region of signal enhancement or phase change due to shunt flow across the defect. MR measurements were compared with templates cut during surgery to match the defect or with ASD diameter determined by balloon sizing at catheterization. ASD size measured from cine MR images (y) agreed closely with catheterization and template standards (x). For major diameter,y=0.78x+5.7,r=.93, and SEE=3.4 mm. On average, spin-echo measurements overestimated major diameter and area of secundum ASDs by 48% and 125%, respectively.ConclusionsPhase-contrast cine MR images acquired in the plane of an ASD define the defect shape by the cross section of the shunt flow stream and allow noninvasive determination of defect size with sufficient accuracy to permit stratification of patients to closure of the defect by catheter-based techniques versus surgery. Spin-echo images, on the other hand, are not adequate for defining ASD size, because septal thinning adjacent to a secundum ASD may appear to be part of the defect.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 52 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3