A Prospective Randomized Evaluation of Implantable Cardioverter-Defibrillator Size on Unipolar Defibrillation System Efficacy

Author:

Jones Gregory K.1,Poole Jeanne E.1,Kudenchuk Peter J.1,Dolack G. Lee1,Johnson George1,DeGroot Paul1,Gleva Marye J.1,Raitt Merritt1,Bardy Gust H.1

Affiliation:

1. From the Division of Cardiology, Department of Medicine, University of Washington School of Medicine, Seattle.

Abstract

Background The active can unipolar implantable cardioverter-defibrillator (ICD) has been shown to defibrillate efficiently, but its current 80-cc size limits use in the pectoral position in many patients. Decreasing can size will facilitate pectoral insertion and will soon be feasible as an inevitable consequence of technological advancements. However, decreasing the can size has the potential to compromise unipolar defibrillation efficacy. It is the purpose of this study, therefore, to prospectively and randomly compare unipolar defibrillation efficacy with 80-cc, 60-cc, and 40-cc can sizes in patients immediately before ICD surgery in anticipation of advances in technology that will make smaller ICDs possible. Methods and Results Twenty-four consecutive patients underwent prospective, randomized evaluation of the effect of ICD can size on defibrillation efficacy during standard ICD surgery. Each patient had the unipolar defibrillation threshold (DFT) measured with 80-cc, 60-cc, or 40-cc active can placed in the left subcutaneous infraclavicular region. The system included a 10.5F tripolar right ventricular electrode that served as the shock anode. The shock waveform used in each instance was a single capacitor biphasic 65% tilt pulse delivered from a 120-μF capacitor. Stored energy at the DFT for the 80-cc, 60-cc, and 40-cc cans were 8.1±4.7 J, 8.7±5.8 J, and 9.5±4.8 J, respectively. There was no statistical significant difference between the DFTs for the three unipolar can electrodes ( P =.39). Leading edge voltage also did not differ significantly among the three unipolar cans (356±92 V, 365±110 V, and 387±94 V, respectively, P =.29). There was, however, a slight progressive increase in resistance with decreasing can size (57±7 Ω, 60±7 Ω, and 65±9 Ω, respectively, P <.001). Conclusions Decreasing can volume from 80 cc to 60 cc to 40 cc does not compromise unipolar defibrillation efficacy despite a slight rise in shock resistance. These findings indicate that technological advances that allow for smaller-volume ICDs will not compromise defibrillation efficacy for unipolar systems.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference17 articles.

Cited by 22 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3