Remodeling of In-Stent Neointima, Which Became Thinner and Transparent Over 3 Years

Author:

Asakura Masanori1,Ueda Yasunori1,Nanto Shinsuke1,Hirayama Atsushi1,Adachi Takayoshi1,Kitakaze Masafumi1,Hori Masatsugu1,Kodama Kazuhisa1

Affiliation:

1. From the Cardiovascular Division, Osaka Police Hospital (M.A., A.H., T.A., K.K.); the Division of Cardiology, The First Department of Medicine, Osaka University School of Medicine (Y.U., M.K., M.H.); and the Cardiovascular Division, Kansai Rosai Hospital, Amagasaki (S.N.), Japan.

Abstract

Background —Recently, it has been reported that the luminal diameter shows phasic changes after stenting: the progression of luminal narrowing followed by its regression. To elucidate the mechanisms involved in the phasic changes in luminal diameter after stenting, we examined the changes in neointimal thickness and the appearance of neointima by a series of angiographic and angioscopic observations for 3 years after stent implantation. Methods and Results —In 12 patients who received a Wiktor coronary stent, serial angiographic and angioscopic examinations were performed immediately, 2 to 4 weeks, 3 months, 6 months, and 3 years after the stenting without repetition of angioplasty. Neointimal thickness was determined by angiography as the difference between stent and luminal diameters. The angioscopic appearance of neointima over the stent was classified as transparent or nontransparent according to the visibility of the majority of the stent. Neointimal thickness increased significantly at 3 months (0.75±0.32 mm) without further changes at 6 months (0.74±0.32 mm). Thereafter, however, it decreased significantly over 3 years (0.51±0.26 mm). The angioscopic appearance was classified as transparent in 8 patients (100%) immediately after stenting, 6 patients (100%) at 2 to 4 weeks, 2 patients (17%) at 3 months, 2 patients (20%) at 6 months, and 7 patients (58%) at 3 years. Conclusions —The neointima became thick and nontransparent until 6 months and then became thin and transparent by 3 years. We conclude that neointimal remodeling exists after stenting and plays a major role in the alteration of coronary luminal diameter after stenting.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 114 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3