Bimodal Distribution of Angiographic Measures of Restenosis Six Months After Coronary Stent Placement

Author:

Schömig Albert1,Kastrati Adnan1,Elezi Shpend1,Schühlen Helmut1,Dirschinger Josef1,Dannegger Felix1,Wilhelm Manfred1,Ulm Kurt1

Affiliation:

1. From the Medizinische Klinik rechts der Isar and Deutsches Herzzentrum (A.S., A.K., S.E., H.S., J.D.) Institut für Medizinische Statistik und Epidemiologie (F.D., M.W., K.U.), Technische Universität München, Munich, Germany.

Abstract

Background Restenosis has been perceived as the tail end of a normal distribution of the response of the vessel to the intervention. However, recent studies have described a bimodal distribution for de novo lesions after percutaneous transluminal coronary angioplasty. This finding suggests that some lesions may be more susceptible for restenosis. Whether this holds true for a wider spectrum of lesions undergoing stent placement is not yet known. The present study analyzes the frequency distribution of angiographic indexes of restenosis 6 months after coronary stent implantation. Methods and Results Quantitative angiographic evaluation was performed in 1084 lesions of 1084 patients before, immediately after, and 6 months after successful Palmaz-Schatz stent placement; this represented 80.4% of patients eligible for follow-up angiography. Principal end points of the analysis were angiographic indexes of restenosis at 6 months. Twenty-two lesions that became totally occluded at follow-up were excluded from most parts of the analysis. Diameter stenosis, minimal luminal diameter (MLD), and lumen loss at 6 months did not follow a normal pattern; the bimodal pattern was demonstrated through deconvolution that yielded two separate normal components delineating two lesion populations, which developed distinctively different degrees of lumen renarrowing. The first and larger subgroup of lesions, which was less prone to restenosis, was centered around a mean value of 27% for diameter stenosis and 2.19 mm for MLD, whereas the second subgroup, with a greater tendency for restenosis, was situated around a mean value of 68% for diameter stenosis and 0.76 mm for MLD. The intersection point between the two theoretical normal distribution components was 53.5% for diameter stenosis and 1.09 mm for MLD at follow-up. Conclusions Frequency-distribution curves of angiographic indexes of restenosis after coronary stent placement have a bimodal pattern, suggesting the existence of two distinct populations with different propensity to restenosis. These findings may encourage future efforts for the timely identification of the subset with a higher risk as the target of specific antirestenotic strategies.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 37 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3