Alternation in the Coronary Blood Flow Velocity Pattern in Patients With No Reflow and Reperfused Acute Myocardial Infarction

Author:

Iwakura Katsuomi1,Ito Hiroshi1,Takiuchi Shin1,Taniyama Yoshiaki1,Nakatsuchi Yoshiaki1,Negoro Shinji1,Higashino Yorihiko1,Okamura Atsunori1,Masuyama Tohru1,Hori Masatsugu1,Fujii Kenshi1,Minamino Takazo1

Affiliation:

1. the Division of Cardiology, Sakurabashi Watanabe Hospital, Osaka, and The First Department of Medicine, Osaka University School of Medicine (T. Masuyama, M.H.), Suita, Japan.

Abstract

Background Experimental and clinical evidence indicates that myocardial ischemia often damages the coronary microvasculature (“no-reflow” phenomenon). In this study, we examined the effect of this phenomenon on the coronary blood flow velocity pattern in patients with reperfused acute myocardial infarction. Methods and Results We measured coronary blood flow velocity after coronary angioplasty in 42 patients with acute myocardial infarction using a Doppler guidewire. Myocardial contrast echocardiography (MCE) was also performed before and after angioplasty. Thirty-one patients showed good contrast reperfusion (MCE reflow), whereas the other 11 showed no reflow (MCE no reflow). Peak velocity and duration of systolic coronary flow were significantly less in patients with MCE no reflow than in those with MCE reflow (8±4 versus 17±10 cm/s and 207±79 versus 289±55 ms, respectively; P <.01). Early systolic retrograde flow was frequently observed in patients with MCE no reflow, whereas it was observed in only 1 patient among those with MCE reflow (95% versus 3%; P <.001). Although peak diastolic flow velocity was similar between the two subsets, diastolic deceleration rate was significantly higher in patients with MCE no reflow than in those with MCE reflow (107±76 versus 56±31 cm/s 2 ; P <.01). Conclusions The coronary flow velocity pattern in patients with the no-reflow phenomenon was characterized by the appearance of systolic retrograde flow, diminished systolic antegrade flow, and rapid deceleration of diastolic flow. Thus, the Doppler guidewire allows us to assess the presence of microvascular dysfunction in AMI.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3