Paired Comparison of Vascular Wall Reactions to Palmaz Stents, Strecker Tantalum Stents, and Wallstents in Canine Iliac and Femoral Arteries

Author:

Barth Klemens H.1,Virmani Renu1,Froelich Jens1,Takeda Toshiaki1,Lossef Steven V.1,Newsome Joseph1,Jones Russell1,Lindisch David1

Affiliation:

1. From the Vascular/Interventional Radiology Division, Georgetown University Medical Center (K.H.B., J.F., T.T., S.V.L., D.L.); the Department of Cardiovascular Pathology, Armed Forces Institute of Pathology (R.V., R.J.); and the Georgetown University Research Resources Facility (J.N.), Washington, DC.

Abstract

Background Palmaz stents, Strecker stents, and Wallstents, all used clinically, differ substantially in their physical characteristics, yet how differently the vascular wall reacts to them has not been demonstrated conclusively. We therefore undertook a side-by-side comparison. Methods and Results One stent was implanted into each canine external iliac and/or the flexing portion of the proximal femoral artery. In 9 dogs, Palmaz stents were placed vis-à-vis Strecker stents, with follow-up of 2 and 4 months. In 7 dogs, Palmaz stents were placed vis-à-vis Wallstents, with 4 months of follow-up. Angiographic midstent luminal diameters immediately after placement and at follow-up as well as midstent cross-sectional areas of neointima were compared for significant differences. In addition, neointimal maturation, medial atrophy, and stent-related trauma were assessed. Angiographically, all arteries remained open. The degree of luminal narrowing by recoil and neointima never reached 50% and was modest for Palmaz stents and Wallstents ( P =.33) but significantly higher for Strecker stents ( P <.0001 compared with Palmaz stents). This corresponded histologically to a significantly thicker neointima ( P =.003) over Strecker than over Palmaz stents but not between Palmaz stents and Wallstents ( P =.18). Neointimal buildup was generally more pronounced in the femoral artery segments than in the iliac segments. Maturation of the neointima over Palmaz stents was much further advanced than over Strecker stents and slightly more advanced than over Wallstents. Pressure-related atrophy of the tunica media was least for Strecker stents and more pronounced but similar for Wallstents and Palmaz stents. Wallstent wire ends caused some wall trauma; several femoral Palmaz stent struts protruded through the media. Conclusions The lower-hoop-strength, higher-profile tantalum Strecker stent is affected by vascular wall recoil and evokes a greater degree of neointima formation than the lower-profile, higher-hoop-strength Palmaz stent and Wallstent. Medial atrophy is pronounced outside the latter two stents. The rigid Palmaz stent can penetrate through the vascular wall in flexing arteries.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 102 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Commercial pure titanium – A potential candidate for cardiovascular stent;Materialwissenschaft und Werkstofftechnik;2022-12

2. A comprehensive review of biological and materials properties of Tantalum and its alloys;Journal of Biomedical Materials Research Part A;2022-02-13

3. Can a self‐expanding pediatric stent expand with an artery? Relationship of stent design to vascular biology;Catheterization and Cardiovascular Interventions;2021-04-06

4. Manufacturing of cardiovascular stents;Metallic Biomaterials Processing and Medical Device Manufacturing;2020

5. Systematical evolution on a Zn–Mg alloy potentially developed for biodegradable cardiovascular stents;Journal of Materials Science: Materials in Medicine;2019-11

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3