Experimental Study of Thrombogenicity and Foreign Body Reaction Induced by Heparin-Coated Coronary Stents

Author:

De Scheerder Ivan1,Wang Kai1,Wilczek Krzysztof1,Meuleman Dirk1,Van Amsterdam Ronald1,Vogel Gerard1,Piessens Jan1,Van de Werf Frans1

Affiliation:

1. From the Department of Cardiology (I.D.S., K. Wang, K. Wilczek, J.P., F.V.D.W.), Gasthuisberg, University Hospital, Leuven, Belgium; and Department of Vascular Pharmacology (D.M., R.V.A., G.V.), Organon International BV, Oss, The Netherlands.

Abstract

Background Results of recent randomized clinical trials have revealed a significant reduction in angiographic restenosis rate when adjunctive stenting was performed after conventional coronary balloon angioplasty. The thrombogenicity of metal stents, however, remains a concern. In the present study, we compare the thrombogenicity of heparin-coated coronary stents with that of bare metallic coronary stents. Methods and Results Thrombogenicity of metallic coronary stents (four heparin-coated and eight bare stents) was studied in a rat arteriovenous shunt model with the use of 125 I-labeled fibrinogen and 51 Cr-labeled platelets. Total clot weight after 30-minute follow-up was significantly lower in the heparin-coated stents compared with the bare stents (8.1±3.7 versus 25.8±4.6 mg; P <.001). Relative 125 I and 51 Cr activities in the stents were significantly higher in the bare stents than in the heparin-coated stents ( 125 I, 1.03±0.43 versus 0.18±0.04, P =.003; 51 Cr, 17.5±6.8 versus 4.4±1.0, P =.004). Subsequently, heparin-coated and bare stents were randomly implanted in the right coronary artery of 20 domestic pigs. Angiographic parameters were similar between both groups at baseline and after 6-week follow-up. Morphometry also did not show a significant difference in lumen area (bare, 1.03±0.83 mm 2 ; heparin-coated, 1.12±0.73 mm 2 ; P =NS) or neointimal hyperplasia (bare, 1.01±0.81 mm 2 ; heparin-coated, 1.21±0.57 mm 2 ; P =NS). Conclusions Heparin coating of metallic coronary stents decreases their thrombogenicity but does not improve late vessel patency and neointimal hyperplasia at follow-up in a porcine coronary model.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司