Relative Efficacy of Monophasic and Biphasic Waveforms for Transthoracic Defibrillation After Short and Long Durations of Ventricular Fibrillation

Author:

Walcott Gregory P.1,Melnick Sharon B.1,Chapman Fred W.1,Jones Janice L.1,Smith William M.1,Ideker Raymond E.1

Affiliation:

1. From the Division of Cardiovascular Diseases, Department of Medicine, University of Alabama at Birmingham (G.P.W., S.B.M., W.M.S., R.E.I.); Georgetown University, Washington, DC (J.L.J.); and Physio-Control Corp (F.W.C.), Redmond, Wash.

Abstract

Background —Recently, interest has arisen in using biphasic waveforms for external defibrillation. Little work has been done, however, in measuring transthoracic defibrillation efficacy after long periods of ventricular fibrillation. In protocol 1, we compared the efficacy of a quasi-sinusoidal biphasic waveform (QSBW), a truncated exponential biphasic waveform (TEBW), and a critically damped sinusoidal monophasic waveform (CDSMW) after 15 seconds of fibrillation. In protocol 2, we compared the efficacy of the more efficacious biphasic waveform from protocol 1, QSBW, with CDSMW after 15 seconds and 5 minutes of fibrillation. Methods and Results —In protocol 1, 50% success levels, ED 50 , were measured after 15 seconds of fibrillation for the 3 waveforms in 6 dogs. In protocol 2, defibrillation thresholds were measured for QSBW and CDSMW after 15 seconds of fibrillation and after 3 minutes of unsupported fibrillation followed by 2 minutes of fibrillation with femoral-femoral cross-circulation. In protocol 1, QSBW had a lower ED 50 , 16.0±4.9 J, than TEBW, 20.3±4.4 J, or CDSMW, 27.4±6.0 J. In protocol 2, QSBW had a lower defibrillation threshold after 15 seconds, 38±10 J, and after 5 minutes, 41.5±5 J, than CDSMW after 15 seconds, 54±19 J, and 5 minutes, 80±30 J, of fibrillation. The defibrillation threshold remained statistically the same for QSBW for the 2 fibrillation durations but rose significantly for CDSMW. Conclusions —In this animal model of sudden death and resuscitation, these 2 biphasic waveforms are more efficacious than the CDSMW at short durations of fibrillation. Furthermore, the QSBW is even more efficacious than the CDSMW at longer durations of fibrillation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 36 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Optogenetic versus Electrical Stimulation of Human Cardiomyocytes: Modeling Insights;Biophysical Journal;2015-04

2. Cardiac optogenetics;American Journal of Physiology-Heart and Circulatory Physiology;2013-05-01

3. Bioelectrodes;Biomaterials Science;2013

4. RECOVER evidence and knowledge gap analysis on veterinary CPR. Part 4: Advanced life support;Journal of Veterinary Emergency and Critical Care;2012-06

5. Implantable Intravascular Defibrillator: Evaluation of Defibrillation Waveforms with Inferior Vena Cava Electrode System;Pacing and Clinical Electrophysiology;2011-01-05

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3