Atrioverter: An Implantable Device for the Treatment of Atrial Fibrillation

Author:

Wellens Hein J. J.1,Lau Chu-Pak1,Lüderitz Berndt1,Akhtar Masood1,Waldo Albert L.1,Camm A. John1,Timmermans Carl1,Tse Hung-Fat1,Jung Werner1,Jordaens Luc1,Ayers Gregory1

Affiliation:

1. From the Academic Hospital Maastricht, Maastricht, the Netherlands (H.J.J.W., C.T.); Queen Mary Hospital, Hong Kong, China (C.-P.L., H.-F.T.); University of Bonn, Bonn, Germany (B.L., W.J.); St Luke’s Medical Center, Milwaukee, Wis (M.A.); University Hospitals of Cleveland, Cleveland, Ohio (A.L.W.); St George’s Hospital, London, UK (A.J.C.); Academic Hospital Gent, Gent, Belgium (L.J.); and InControl Inc, Redmond, Calif (G.A.).

Abstract

Background —During atrial fibrillation, electrophysiological changes occur in atrial tissue that favor the maintenance of the arrhythmia and facilitate recurrence after conversion to sinus rhythm. An implantable defibrillator connected to right atrial and coronary sinus defibrillation leads allows prompt restoration of sinus rhythm by a low-energy shock. The safety and efficacy of this system, called the Atrioverter, were evaluated in a prospective, multicenter study. Methods and Results —The study included 51 patients with recurrent atrial fibrillation who had not responded to antiarrhythmic drugs, were in New York Heart Association Heart failure class I or II, and were at low risk for ventricular arrhythmias. The atrial defibrillation threshold had to be ≤240 V during preimplant testing. Atrial fibrillation detection, R-wave shock synchronization, and defibrillation threshold were tested at implantation and during follow-up. Shock termination of spontaneous episodes of atrial fibrillation was performed under physician observation. Results are given after a minimum of 3 months of follow-up. During a follow-up of 72 to 613 days (mean, 259±138 days), 96% of 227 spontaneous episodes of atrial fibrillation in 41 patients were successfully converted to sinus rhythm by the Atrioverter. In 27% of episodes, several shocks were required because of early recurrence of atrial fibrillation. Shocks did not induce ventricular arrhythmias. Most patients received antiarrhythmic medication during follow-up. In 4 patients, the Atrioverter was removed: in 1 because of infection, in 1 because of cardiac tamponade, and in 1 because of frequent episodes of atrial fibrillation requiring His bundle ablation. Conclusions —With the Atrioverter, prompt and safe restoration of sinus rhythm is possible in patients with recurrent atrial fibrillation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 225 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3