Adenosine-Induced Coronary Vasodilatation During Transesophageal Doppler Echocardiography

Author:

Redberg Rita F.1,Sobol Youri1,Chou Tony M.1,Malloy Mary1,Kumar Shantha1,Botvinick Eli1,Kane John1

Affiliation:

1. From the Cardiovascular Research Institute, the Cardiology Division of the Department of Medicine, and the John Henry Mills Echocardiography Laboratory of the University of California, San Francisco.

Abstract

Background Less invasive methods are replacing traditional invasive means of measuring coronary flow reserve (CFR). Transesophageal echocardiography (TEE) is becoming a useful tool for evaluation of coronary artery disease and has recently been used to measure CFR. This has always been done using dipyridamole, but adenosine has a greater vasodilator potency and more favorable kinetics than dipyridamole. This study was done to evaluate the hypothesis that adenosine is safe, rapid, and accurate in measuring coronary blood flow reserve by TEE Doppler. Methods and Results Forty-nine patients who had recently undergone angiography had a transesophageal echocardiogram with visualization of the coronary arteries and measurement of blood flow velocity in the left anterior descending coronary artery (LAD) during adenosine infusion of 0.14 mg/kg per minute. Angiograms were analyzed by quantitative coronary angiography, and significant stenosis was defined as >70% lumenal diameter narrowing. Thirty-nine of the 49 patients did not have a significant LAD stenosis (group 1); the remainder had significant disease (group 2). Good spectral Doppler recordings of blood flow velocity in the LAD were obtained in 41 of 46 patients (89%). There were no significant differences in baseline coronary blood flow velocities between the two groups. Hyperemic to baseline flow ratios were significantly higher in patients without significant LAD stenosis for peak (2.83±1.04 versus 1.78±0.36) and mean (2.68±0.96 versus 1.75±0.39) diastolic velocity. A CFR ratio >2.1 had a sensitivity of 86%, a specificity of 79%, a positive predictive value of 46%, and a negative predictive value of 96% for the absence of critical LAD stenosis. The infusion was well tolerated. It had to be prematurely terminated in only 3 patients (6.5%), and they were asymptomatic. No patient experienced chest pain, palpitations, or flushing. Intraobserver and interobserver variabilities were low, and reproducibility of data was good (<4%). Conclusions Adenosine Doppler TEE is an effective, rapid, safe, and superior means of measuring CFR ratio. This method is convenient for serial measurements of CFR as well as in clinical settings such as evaluation of syndrome X, cardiomyopathy, and aortic regurgitation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 95 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3