Comparison Between 201 Tl and 99m Tc Sestamibi Uptake During Adenosine-Induced Vasodilation as a Function of Coronary Stenosis Severity

Author:

Glover David K.1,Ruiz Mirta1,Edwards Nathaniel C.1,Cunningham Michael1,Simanis Juris P.1,Smith William H.1,Watson Denny D.1,Beller George A.1

Affiliation:

1. From the Experimental Cardiology Laboratory, Division of Cardiology, Department of Medicine, University of Virginia, Charlottesville.

Abstract

Background Myocardial uptake of either 201 Tl or 99m Tc-sestamibi (sestamibi) is known to plateau at high coronary flow rates. However, few direct comparisons have been made between these tracers to determine what effect differences in the uptake plateau for the two tracers may have on the detection of coronary stenoses of various severities. Methods and Results Twenty-two dogs were instrumented with flow transducers on the left anterior descending (LAD) and circumflex (LCx) arteries. In 6 nonstenotic dogs, adenosine was infused directly into the LAD, whereas 16 dogs with either critical (n=7) or mild (n=9) LAD stenoses received an intravenous infusion. At peak flow, 201 Tl (0.5 mCi), sestamibi (5 to 8 mCi), and radiolabeled microspheres were injected simultaneously. Five minutes later, dogs were killed, and ex vivo imaging of heart slices and gamma-well counting of multiple myocardial samples was performed. Neither 201 Tl nor sestamibi uptake increased in direct proportion to flow. In the 6 nonstenotic dogs, a fivefold increase in LAD flow increased 201 Tl and sestamibi uptake by only 202±6% and 138±4%, respectively ( P <.0001). In the dogs with critical stenosis, the ratios of stenotic to normal activity by well counting for 201 Tl (0.37±0.05) and sestamibi (0.53±0.06) underestimated the microsphere-determined flow disparity (0.17±0.03) ( P <.005), but the degree of underestimation was greater for sestamibi ( P =.001). Similarly, in the dogs with mild stenosis, the stenotic-to-normal ratio for 201 Tl (0.62±0.04) approximated the flow ratio (0.43±0.04) better than sestamibi (0.79±0.03) ( P <.0001). Sestamibi defects, however, were visually identifiable on the images of the myocardial slices. By image quantification, sestamibi defect magnitude (LAD-to-LCx count ratio) in the critical stenosis group (0.62±0.05) was significantly less than in the mild stenosis group (0.80±0.02) ( P <.01). Conclusions Thus, with adenosine-induced hyperemic flow, both 201 Tl and sestamibi significantly underestimated the magnitude of the flow disparity between stenotic and normal perfusion beds. The degree of underestimation was greater for sestamibi. The clinical implication of these experimental findings for vasodilator perfusion imaging remains to be determined, since factors such as greater redistribution and scatter with 201 Tl could offset its advantages.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3