Thermal Latency in Radiofrequency Ablation

Author:

Wittkampf Fred H.M.1,Nakagawa Hiroshi1,Yamanashi William S.1,Imai Shinobu1,Jackman Warren M.1

Affiliation:

1. From the Heart Lung Institute, Department of Cardiology, University Hospital Utrecht, the Netherlands (F.H.M.W.), and the Cardiovascular Section, Department of Medicine, University of Oklahoma Health Sciences Center and the Department of Veterans Affairs Medical Center, Oklahoma City, Okla.

Abstract

Background Progression of unintentionally induced atrioventricular delay is occasionally observed directly after termination of radiofrequency delivery in the vicinity of the atrioventricular node. We postulated that the application of a radiofrequency pulse may result in a tissue temperature rise that continues after the pulse. Methods and Results Using the thigh muscle preparation, 5-, 10-, 20-, and 30-second pulses were applied at 30 to 40 W via a standard 4-mm tip electrode with 10-g contact pressure. Forty-one undisturbed pulses were delivered while recording intramural temperatures at 2-, 4-, and 7-mm depth. Maximal “thermal latency” was observed with the shortest pulse duration and at greatest depth. With 5-second applications, tissue temperature at 7-mm depth peaked 11.6 seconds after termination of radiofrequency delivery and stayed above end-of-pulse value as long as 34.5 seconds after the pulse. The additional rise in tissue temperature was 2.9°C. If only recordings within the lesion border zone were considered, the duration of latency was maximal with 10-second pulses: an additional gain in tissue temperature of 3.4°C was observed 6.4 seconds after the pulse while tissue temperature stayed above end-of-pulse value during 18.3 seconds. Conclusions With relatively short applications, tissue temperature continues to rise after termination of radiofrequency delivery. This “thermal latency” may result in lesion growth after the pulse and may so explain the incidentally observed progression of conduction block after short pulses in the vicinity of the atrioventricular node. It also may explain the apparent discrepancy between lesion growth rate and intramural temperature rise studies.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3