Enhanced Intracoronary Thrombolysis With Urokinase Using a Novel, Local Drug Delivery System

Author:

Mitchel Joseph F.1,Fram Daniel B.1,Palme Donald F.1,Foster Rosemary1,Hirst Jeffrey A.1,Azrin Michael A.1,Bow Laurine M.1,Eldin Adel M.1,Waters David D.1,McKay Raymond G.1

Affiliation:

1. From the Departments of Internal Medicine and Cardiology, Hartford Hospital, University of Connecticut, Hartford.

Abstract

Background Current pharmacological regimens for treating intracoronary thrombus in the cardiac catheterization laboratory generally involve the administration of thrombolytic agents that result in a systemic fibrinolytic state and/or require prolonged arterial drug infusion. The purpose of the present study was to assess a new technique for treating intracoronary thrombus consisting of the local infusion of limited quantities of urokinase with a novel drug delivery device. Methods and Results The Dispatch coronary infusion catheter is a new local drug delivery system that allows for the prolonged infusion of therapeutic agents at an angioplasty site while distal coronary flow is maintained. Three experimental protocols were performed to determine the in vitro, in vivo, and clinical efficacy of this device. First, in vitro thrombolysis of fresh, porcine thrombus trapped in a 4-mm plastic tube with a 50% constriction and perfused with 20% porcine plasma was measured. Twenty-three thrombi were weighed before and after no treatment (n=5), “systemic” urokinase administration (n=4), local infusion of 150 000 U urokinase with a standard end-hole catheter (n=4), local infusion of saline with the Dispatch catheter (n=5), and local infusion of 150 000 U urokinase with the Dispatch catheter (n=5). Second, 25 porcine coronary arteries in 23 pigs were dilated in vivo with conventional balloon angioplasty and then treated with 123 I-labeled urokinase that was administered either by the Dispatch catheter (150 000 U; n=16), intravenous systemic bolus (1 000 000 U; n=3), guiding catheter infusion (500 000 U; n=3), or local end-hole catheter infusion (150 000 U; n=3). All vessels were subsequently harvested to quantify intramural deposition and subsequent washout of urokinase at the angioplasty site. Finally, 19 patients with angiographic evidence of intracoronary thrombus were treated with local urokinase infusion with the Dispatch catheter either before or after balloon angioplasty or directional atherectomy. In vitro studies demonstrated that infusion of urokinase with the Dispatch catheter decreased thrombus weight by 66% compared with no treatment (−25%), “systemic” urokinase administration (25%), end-hole catheter urokinase infusion (32%), or infusion of saline by the Dispatch catheter (32%) ( P ≤.005). In vivo studies demonstrated immediate deposition of 0.12% of the urokinase delivered by the Dispatch catheter to the angioplasty site, compared with 0.0007% with systemic bolus, 0.003% with guiding catheter infusion, and 0.007% with local infusion with an end-hole catheter ( P <.001). Urokinase deposited by the Dispatch catheter persisted intramurally for at least 5 hours. Patient studies demonstrated reduction of thrombus-containing stenoses and complete disappearance of intracoronary thrombus in all cases in which 150 000 U urokinase was locally infused over 30 minutes. There was no evidence of abrupt closure, distal embolization, or no reflow in any patient. Conclusions Local urokinase delivery with the Dispatch catheter can result in rapid and complete intracoronary thrombolysis using substantially less drug than standard thrombolytic techniques. Intramural deposition of drug with this technique creates a local reservoir of urokinase that may provide prolonged thrombolytic activity at the infusion site.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3