Relaxation–Systolic Pressure Relation

Author:

Gillebert Thierry C.1,Leite-Moreira Adelino F.1,De Hert Stefan G.1

Affiliation:

1. the Cardiovascular Research Unit (Department of Experimental Surgery), the Division of Cardiology (T.C.G.), and the Division of Anesthesiology (S.G.D.), University of Antwerp, Belgium; and the Laboratory of Physiology (A.F.L.-M.), Faculty of Medicine, University of Porto, Hospital de Sa˜o Joa˜o, Oporto, Portugal.

Abstract

Abstract This contribution reviews the regulation of left ventricular pressure (LVP) fall by load and relates this regulation to left ventricular contractility. Load regulation of LVP fall has to be distinguished from neurohumoral regulation, from effects induced by arterial reflected waves and from long-term load effects on contractility. The response of LVP fall to a moderate elevation of systolic LVP is highly variable. It depends on the ratio between the actual systolic pressure and peak isovolumetric pressure, defined as “relative load”. Up to a relative load of 81% to 84%, LVP fall accelerates. Above this relative load, LVP fall decelerates. Depending on the level of relative load there is a wide variety of effects ranging from moderate acceleration of LVP fall to marked deceleration of LVP fall. Acceleration of LVP fall in response to a load elevation is associated with normal cardiac function, while slowing of LVP fall is associated with impaired cardiac function. Similar but opposite effects are observed with reductions of systolic LVP. Effects of changes in systolic LVP on time constant τ reveal a fair correlation with systolic elastance (Ees), peak dP/dt max and regional fractional shortening (or ejection fraction). There is an excellent correlation with measured isovolumetric LVP, indicating that contraction-relaxation coupling is close when contractility is expressed in terms of peak isovolumetric pressure. Assessment of contractility with systolic LVP-relaxation relation is precise and load independent and can be performed with the sole use of a high-fidelity pressure gauge positioned in the left ventricular cavity.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3