Role of Right Atrial Endocardial Structures as Barriers to Conduction During Human Type I Atrial Flutter

Author:

Olgin Jeffrey E.1,Kalman Jonathan M.1,Fitzpatrick Adam P.1,Lesh Michael D.1

Affiliation:

1. From the Section of Cardiac Electrophysiology, Department of Medicine and Cardiovascular Research Institute, University of California San Francisco.

Abstract

Background The importance of barriers in atrial flutter has been demonstrated in animals. We used activation and entrainment mapping, guided by intracardiac echocardiography (ICE), to determine whether the crista terminalis (CT) and eustachian ridge (ER) are barriers to conduction during typical atrial flutter in humans. Methods and Results In eight patients, ICE was used to guide the placement of 20-pole and octapolar catheters along the CT and interatrial septum and a roving catheter to nine sites: just posterior (1) and anterior (2) to the CT along the lateral right atrium, at the fossa ovalis (3), and just posterior and anterior to the ER at the low posterolateral (4 and 5), low posterior (6 and 7), and low posteromedial (8 and 9) right atrium. Entrainment was performed, and each site was considered within the flutter circuit if the postpacing interval–flutter cycle length (PPI−FCL) and the stimulus time–activation time (stim time−act time) were <10 msec. Split potentials were recorded along the CT with components activated in a low-to-high pattern and a high-to-low pattern. Conduction times, as percentage of FCL, were significantly different at sites on either side of the CT and ER: site 1 (33±13%) and site 2 (43±12%) ( P =.02), site 4 (48±24%) and site 5 (75±8.9%) ( P =.02), and site 6 (22±10%) and site 7 (82±5.3%) ( P =.0009). During entrainment, no surface fusion was observed at sites 5, 7, or 9. The PPI−FCL and stim time−act time were not significantly different than 0 at sites 2, 7, 5, or 9, indicating that they were within the flutter circuit, whereas sites 1, 3, 4, and 6 were not. Conclusions ICE enabled the correlation of functional electrophysiological properties with specific anatomic landmarks, identifying the CT and ER as barriers to conduction during human atrial flutter.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 442 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3