Assessment of Small-Diameter Aortic Mechanical Prostheses

Author:

Marcus Richard H.1,Heinrich Russell S.1,Bednarz James1,Lupovitch Stephen1,Abruzzo Joseph1,Borok Raphael1,Vandenberg Byron1,Kerber Richard E.1,Piccione William1,Yoganathan Ajit P.1,Lang Roberto M.1

Affiliation:

1. From the Noninvasive Cardiac Imaging Laboratory (R.H.M., J.B., S.L., J.A., R.M.L.), University of Chicago Medical Center, Chicago, Ill; Cardiovascular Fluid Mechanics Laboratory (R.S.H., A.P.Y.), Georgia Institute of Technology, Atlanta, Ga; Departments of Pathology (R.B.) and Cardiovascular Surgery (W.P.), Rush-Presbyterian–St. Lukes’ Medical Center, Chicago, Ill; and Echocardiography Laboratory (B.V., R.E.K.), University of Iowa Hospital, Iowa City.

Abstract

Background —Noninvasive assessment of functionally stenotic small-diameter aortic mechanical prostheses is complicated by theoretical constraints relating to the hemodynamic relevance of Doppler-derived transprosthetic gradients. To establish the utility of Doppler echocardiography for evaluation of these valves, 20-mm Medtronic Hall and 19-mm St Jude prostheses were studied in vitro and in vivo. Methods and Results —Relations between the orifice transprosthetic gradient (equivalent to Doppler), the downstream gradient in the zone of recovered pressure (equivalent to catheter), and fluid mechanical energy losses were examined in vitro. Pressure-flow relations across the 2 prostheses were evaluated by Doppler echocardiography in vivo. For both types of prosthesis in vitro, the orifice was higher than the downstream gradient ( P <0.001), and fluid mechanical energy losses were as strongly correlated with orifice as with downstream pressure gradients ( r 2 =0.99 for both). Orifice and downstream gradients were higher and fluid mechanical energy losses were larger for the St Jude than the Medtronic Hall valve (all P <0.001). Whereas estimated effective orifice areas for the 2 valves in vivo were not significantly different, model-independent dynamic analysis of pressure-flow relations revealed higher gradients for the St Jude than the Medtronic Hall valve at a given flow rate ( P <0.05). Conclusions —Even in the presence of significant pressure recovery, the Doppler-derived gradient across small-diameter aortic mechanical prostheses does have hemodynamic relevance insofar as it reflects myocardial energy expenditure. Small differences in function between stenotic aortic mechanical prostheses, undetectable by conventional orifice area estimations, can be identified by dynamic Doppler echocardiographic analysis of pressure-flow relations.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 17 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Cardiac Valves;Problem Solving in Cardiovascular Imaging;2013

2. Avoiding Patient–Prosthesis Mismatch;JACC: Cardiovascular Imaging;2011-10

3. Exercise Hemodynamics in Valvular Heart Disease;Current Cardiology Reports;2011-02-12

4. Double valve endocarditis and evolving paraannular abscess formation;Aortic Root Surgery;2010

5. Recommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler Ultrasound;Journal of the American Society of Echocardiography;2009-09

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3