Left Ventricular Function, Twist, and Recoil After Mitral Valve Replacement

Author:

DeAnda Abe1,Komeda Masashi1,Nikolic Srdjan D.1,Daughters George T.1,Ingels Neil B.1,Miller D. Craig1

Affiliation:

1. From the Department of Cardiovascular and Thoracic Surgery, Stanford (Calif) University School of Medicine (A.D., M.K., D.C.M.); the Cardiac Surgery Section, Department of Veterans Affairs Medical Center, Palo Alto, Calif (D.C.M.); and the Research Institute of the Palo Alto Medical Foundation, Palo Alto, Calif (S.D.N., G.T.D., N.B.I.).

Abstract

Background Preservation of the mitral subvalvular apparatus during mitral valve replacement (MVR) has become more popular, in part because of the clinically and experimentally demonstrated more optimal left ventricular (LV) performance after surgery; the mechanisms responsible for this beneficial influence, however, have not been clearly elucidated. Methods and Results Fourteen dogs underwent placement of 26 myocardial markers into the LV and septum. One week later, the animals were studied while awake, sedated, and atrially paced (120 beats per minute) both under baseline conditions and after inotropic stimulation (calcium). The animals then underwent MVR and were randomized into either chord-sparing (MVR-Intact) or chord-severing (MVR-Cut) techniques. Two weeks later, the animals were studied under the same conditions. LV systolic function was assessed by the slope of the end-systolic pressure-volume relation (E es ); early LV diastolic filling was analyzed by the pressure-time constant of relaxation (τ). The instantaneous longitudinal gradient of torsional deformation for the LV (twist) was also calculated, as were the changes in twist with respect to time during systole and early diastole (LV recoil). Intergroup comparison showed a trend toward increased contractility (E es , P =.061, before versus after MVR), as well as faster relaxation for the MVR-Intact group. Concurrent analysis of LV systolic function and the rate of systolic twist revealed a significant inverse relation, which disappeared after MVR when the chordae were severed. Conclusions These observations suggest that the mitral subvalvular apparatus acts as a modulator of LV systolic torsional deformation into LV pump (or ejection) performance.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 41 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3