Serial Follow-up After Optimized Ultrasound-Guided Deployment of Palmaz-Schatz Stents

Author:

Mudra Harald1,Regar Evelyn1,Klauss Volker1,Werner Frank1,Henneke Karl-Heinz1,Sbarouni Efthia1,Theisen Karl1

Affiliation:

1. the Department of Medicine, Division of Cardiology, Klinikum Innenstadt, University of Munich, Germany.

Abstract

Background The effects of ultrasound-guided high-pressure stenting on late stent and reference segment dimensions are unknown. In this study, we report about angiographic and ultrasound measurements to assess the amount and distribution of neointimal ingrowth within the stent and the changes of plaque burden and dimensions within the reference segments. Methods and Results Sixty-eight consecutive patients with 72 lesions received single or multiple Palmaz-Schatz coronary stents with a standardized protocol for stent optimization under ultrasound guidance. The residual angiographic diameter stenosis was 3±12% (reference diameter, 3.16±0.61 mm). At follow-up 4.8±2.5 months later, angiography revealed a diameter stenosis of 27±21% with a restenosis rate of 15.3% (confidence interval: 7.8% to 25.6%). Lumen renarrowing within the stent was exclusively due to neointimal ingrowth; no stent compression was observed. The neointima covered 20±20% of the stent area and was more pronounced in the midportion of the stent. Volumetric assessment performed in 26 patients resulted in 13±14% or 65±28% of the stent volume occupied by neointimal ingrowth in patients without or with restenosis, respectively. Vessel remodeling had an impact on lumen dimensions only at reference sites but not within the stent. Plaque burden of 46±11% and 48±11% at the proximal and distal reference sites, respectively, did not show a relevant progression during the follow-up. Conclusions Serial ultrasound analyses did not show any evidence of stent compression or relevant vessel remodeling. Restenosis was solely due to neointimal ingrowth. Despite a considerable plaque burden within the reference segments, there was no relevant progression of the disease adjacent to the stent.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 139 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3