Proximal Jet Size by Doppler Color Flow Mapping Predicts Severityof Mitral Regurgitation

Author:

Mele Donato1,Vandervoort Pieter1,Palacios Igor1,Rivera J. Miguel1,Dinsmore Robert E.1,Schwammenthal Ehud1,Marshall Jane E.1,Weyman Arthur E.1,Levine Robert A.1

Affiliation:

1. From the Noninvasive (D.M., P.V., J.M.R., E.S., J.E.M., A.E.W., R.A.L.) and Invasive (I.P., R.E.D.) Cardiac Laboratories, Massachusetts General Hospital and Harvard Medical School, Boston, Mass.

Abstract

Background Recent studies have shown that many instrument and physiological factors limit the ability of color Doppler total jet area within the receiving chamber to predict the severity of valvular regurgitation. In contrast, the proximal or initial dimensions of the jet as it emerges from the orifice have been shown to increase directly with orifice size and to correlate well with the severity of aortic insufficiency. Only limited data, however, are available regarding the value of proximal jet size in mitral regurgitation, and it has not been examined in short-axis or transthoracic views. The purpose of the present study, therefore, was to evaluate the relation between proximal jet size and other measures of the severity of mitral regurgitation. Methods and Results In 49 patients, the anteroposterior height of the proximal jet as it emerges from the mitral valve was measured in the parasternal long-axis view; proximal jet width and area were measured in the short-axis view at the same level. Results were compared with regurgitant volume and fraction by pulsed Doppler subtraction of aortic and mitral flows in 47 patients without more than trace aortic insufficiency; with angiographic grade determined within 24 hours in 33 catheterized patients; and with angiographic regurgitant fraction in 13 patients who were in normal sinus rhythm and had no significant aortic and tricuspid insufficiency. Proximal jet height, width, and area correlated well with Doppler regurgitant volume and fraction ( r =.86 to .95; SEE=7.7 to 9.0 mL; 5.9% to 7.3%). Proximal jet size could also be used to distinguish angiographic grades of mitral regurgitation with minimal overlap ( P <.0001) and correlated well with angiographic regurgitant fraction ( r =.85 to .91; SEE=4.1% to 5.1%). Conclusions Proximal jet size correlates well with established measures of the severity of mitral regurgitation. It is conveniently available with transthoracic clinical scanning and should be useful in the routine evaluation of patients with mitral regurgitation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 130 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. In Memoriam: Arthur E. Weyman, MD, FASE;Journal of the American Society of Echocardiography;2024-08

2. Obituary: Arthur E. Weyman, 1941–2024;European Heart Journal - Cardiovascular Imaging;2024-07-11

3. Assessment of the mechanism of mitral valve prolapse in children: An echocardiography study;Echocardiography;2023-05-31

4. Quantification of primary mitral regurgitation by echocardiography: A practical appraisal;Frontiers in Cardiovascular Medicine;2023-03-10

5. Functional Mitral Regurgitation Outcome and Grading in Heart Failure With Reduced Ejection Fraction;JACC: Cardiovascular Imaging;2021-12