Alterations in Ultrasonic Backscatter During Exercise-Induced Myocardial Ischemia in Humans

Author:

Vitale Dino F.1,Bonow Robert O.1,Gerundo Giusto1,Pelaggi Nicola1,Lauria Gianfranco1,Leosco Dario1,Coltorti Fernando1,Bordini Carlo1,Rengo Carlo1,Rengo Franco1

Affiliation:

1. From the University of Naples, Federico II Faculty of Medicine, Cattedra di Geriatria, Naples, Italy, and Northwestern University Medical School, Division of Cardiology, Chicago, Ill (R.O.B.).

Abstract

Background Experimentally induced myocardial ischemia in animals causes tissue modifications that alter characteristics of the ultrasonic beam backscattered from the myocardial muscle. Alterations of backscatter parameters have been evidenced in human subjects with acute or remote myocardial infarction and during ischemia induced by angioplasty balloon occlusion or pharmacological stimuli. The effects of transient effort ischemia in humans have not been reported. The purpose of this study is to assess ultrasonic backscatter parameter changes induced by transient effort myocardial ischemia in human subjects. Methods and Results Nineteen patients with single left anterior descending coronary stenosis and 15 healthy subjects underwent ultrasonic backscatter analysis (parasternal long-axis view) at rest, immediately after a supine stress test, and 30 minutes later. Two windows were selected in each ultrasonic study: one encompassing the septum; the other, the posterior wall. Integrated backscatter was computed throughout the cardiac cycle, yielding a power curve relative to the midmyocardial region of the myocardial wall (excluding pericardial and endocardial borders). Five parameters were computed from the backscatter power curve: the maximum−minimum difference, amplitude and phase of the first harmonic Fourier fitting, phase-weighted amplitude, and time-averaged integrated backscatter difference from rest (an index of overall myocardial reflectivity). This protocol allowed comparison of the backscatter data from a region at risk of ischemia (the septum) with that from a region normally perfused (posterior wall) and a comparison with the same regions of the control group during the three ultrasonic studies. All backscatter indexes in the septum were altered significantly by exercise compared with rest values, whereas no changes were found in the normally perfused posterior wall or in the septum of the control group. All modified parameters returned to baseline values at the time of the recovery study. Conclusions These data indicate that transient, exercise-induced ischemia is associated with reduction of the cardiac cycle–dependent variation of the integrated backscatter power curve, a temporal shift in the nadir of the power curve with respect to the R wave (phase increase), and a small but detectable increase of myocardial reflectivity. These changes may be detected noninvasively in humans with ultrasonic backscatter analysis.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3