Right atrial and right ventricular transmural pressures in dogs and humans. Effects of the pericardium.

Author:

Hamilton D R1,Dani R S1,Semlacher R A1,Smith E R1,Kieser T M1,Tyberg J V1

Affiliation:

1. Department of Medicine, Foothills Provincial Hospital, Calgary, Alberta, Canada.

Abstract

BACKGROUND To determine the transmural pressure-dimension relations of the right atrium (RA) and right ventricle (RV) before and after pericardiectomy, six open-chest dogs were instrumented with pericardial balloons placed over the RA and RV free walls. METHODS AND RESULTS PA appendage dimensions and RV free-wall segment lengths were measured using sonomicrometry. Intact-pericardium RA and RV transmural pressures were calculated by subtracting the pericardial pressures (measured using balloons) from the cavitary pressures. Pooled data from six animals with pericardium intact indicate that at RA and RV cavitary pressures of 5, 10, and 15 mm Hg, RV pericardial pressure was 4.3 +/- 0.3, 8.6 +/- 1.0, and 13.3 +/- 1.5 mm Hg, respectively, and RA pericardial pressure was 4.8 +/- 0.3, 9.6 +/- 0.6, and 14.6 +/- 0.6 mm Hg, respectively (mean +/- SD). With calculated unstressed dimensions, the cavity dimension data were normalized to strain (in percent). We determined that in the dog, RV strain would increase by 14% and RA by 68% to maintain cavitary pressure at 10 mm Hg on pericardiectomy. To compare these results with clinical data, RV (n = 7) and RA (n = 6) transmural pressures were measured using balloons in patients (age, 19 to 76 years) undergoing cardiac surgery. RA transmural pressure of six patients was 1.0 +/- 1.5 mm Hg when central venous pressures (CVPs) ranged from 3 to 16 mm Hg. RV transmural pressure equaled 1.2 +/- 1.9, 2.3 +/- 1.9, and 3.4 +/- 2.0 mm Hg when CVP was 5, 10, and 15 mm Hg, respectively. CONCLUSIONS Pericardial constraint (as evaluated by the ratio of pericardial to intracavitary pressures when CVP is 10 mm Hg) accounted for 96% of RA cavitary pressure in the dog and 89% in humans and at least 86% of RV cavitary pressure in the dog and 77% in humans.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3