Improving Active Compression-Decompression Cardiopulmonary Resuscitation With an Inspiratory Impedance Valve

Author:

Lurie Keith G.1,Coffeen Paul1,Shultz Jeffrey1,McKnite Scott1,Detloff Barry1,Mulligan Kate1

Affiliation:

1. From the Cardiac Arrhythmia Center at the University of Minnesota, Minneapolis.

Abstract

Background Active compression-decompression (ACD) cardiopulmonary resuscitation (CPR) has recently been demonstrated to provide significantly more blood flow to vital organs during cardiac arrest. To further enhance the effectiveness of this technique, we tested the hypothesis that intermittent impedance to inspiratory gas exchange during the decompression phase of ACD CPR enhances vital organ blood flow. Methods and Results ACD CPR was performed with a pneumatically driven automated compression-decompression device in a porcine model of ventricular fibrillation (VF). Nine pigs were randomized to receive ACD CPR alone, while 8 pigs received ACD CPR plus intermittent impedance to inspiratory gas exchange with a threshold valve set to 40 cm H 2 O. Results comparing 2 minutes of ACD CPR alone versus ACD CPR with the inspiratory impedance threshold valve (ITV) revealed significantly higher mean (±SEM) coronary perfusion pressures (diastolic aortic minus diastolic right atrial pressures) in the ITV (31.0±2.3 mm Hg) group versus with ACD CPR alone (21±3.6 mm Hg) ( P <.05). Total left ventricular and cerebral blood flows, determined by radiolabeled microspheres, were 0.77±0.095 and 0.47±0.06 mL/min per gram, respectively, with ACD CPR plus the ITV versus 0.45±0.1 and 0.32±0.016 mL/min per gram, respectively, with ACD CPR alone ( P <.05). Similar improvements in the ITV group were observed after 7 minutes of ACD CPR. After 16 minutes of VF and 13 minutes of ACD CPR, 6 of 8 pigs in the ITV group were successfully resuscitated with less than three successive 150-J shocks, whereas only 2 of 9 pigs with ACD CPR alone were resuscitated with equivalent energy levels ( P <.02). With up to three additional and successive 200-J shocks, all pigs in the ITV group and 7 of 9 pigs with ACD CPR alone were resuscitated ( P =.18). Conclusions Intermittent impedance to inspiratory flow of respiratory gases during ACD CPR significantly improves coronary perfusion pressures and vital organ blood flow and lowers defibrillation energy requirements in a porcine model of VF.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 159 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3