Provocation of Hypotension During Head-Up Tilt Testing in Subjects With No History of Syncope or Presyncope

Author:

Natale Andrea1,Akhtar Masood1,Jazayeri Mohammad1,Dhala Anwer1,Blanck Zalmen1,Deshpande Sanjay1,Krebs Anita1,Sra Jasbir S.1

Affiliation:

1. From the Electrophysiology Laboratory, Milwaukee Heart Institute of Sinai Samaritan Medical Center and St Luke’s Hospital, University of Wisconsin-Milwaukee Clinical Campus, Milwaukee, Wis.

Abstract

Background Head-up tilt test is increasingly being used to evaluate patients with syncope. This study was designed to evaluate the specificity of head-up tilt testing using different tilt angles and isoproterenol infusion doses in normal volunteers with no prior history of syncope or presyncope. Methods and Results One hundred fifty volunteers were randomized to two groups of 75 each. In group 1, subjects were further randomized to have head-up tilt testing at a 60, 70, or 80 degree angle at baseline followed by repeat tilt testing during a low-dose isoproterenol infusion that increased the heart rate by an average of 20%. In group 2, after having a baseline head-up tilt test at a 70 degree angle for a maximum of 20 minutes, subjects were randomized to have a repeat tilt table testing at a 70 degree angle during a low-dose, 3 μg/min, or 5 μg/min isoproterenol infusion. In group 1, syncope or presyncope along with hypotension developed in 2 subjects during the baseline test at 60 and 70 degrees of tilt and in 5 subjects during tilting at 80 degrees. The addition of low-dose isoproterenol reduced the specificity minimally from 92% to 88% at both 60 and 70 degrees of tilt but substantially to 60% at an 80 degree angle. However, 6 of the 10 subjects with a positive test at an 80 degree angle had an abnormal response after 10 minutes of tilt testing. In group 2, using various isoproterenol doses with tilt table testing at a 70 degree angle, low-dose (mean infusion dose, 1.5±0.45 μg/min), 3 μg/min, and 5 μg/min isoproterenol infusions elicited an abnormal response in 1 (4%), 5 (20%), and 14 (56%) of the subjects, respectively. Using multiple logistic regression analysis, head-up tilt testing at an 80 degree angle ( P =.01) or during 3 μg/min ( P =.02) and 5 μg/min isoproterenol infusion rates ( P <.001) was the most significant predictor of an abnormal response. Conclusions Head-up tilt testing at a 60 or 70 degree angle with or without low-dose isoproterenol infusion provides an adequate specificity. Caution is needed, however, in interpreting the results if the head-up tilt test at 80 degrees is extended beyond 10 minutes or if high doses of isoproterenol are used.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 159 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3