Anatomically and Physiologically Based Reference Level for Measurement of Intracardiac Pressures

Author:

Courtois Michael1,Fattal Peter G.1,Kovács Sandor J.1,Tiefenbrunn Alan J.1,Ludbrook Philip A.1

Affiliation:

1. From the Cardiovascular Division, Washington University School of Medicine, St Louis, Mo.

Abstract

Background Many reference levels have been proposed for the measurement of intracardiac pressures, but none have met with universal acceptance. In the first part of our study, we evaluated 10 cardiologists’ understanding of how hydrostatic pressure influences intracardiac pressures as measured with fluid-filled catheters. In the second part, we proposed and validated a new zero level (H): the uppermost blood level in the left ventricular (LV) chamber relative to the anterior chest wall for a patient in the supine position. A comparison was made of LV minimum diastolic pressure measured by reference to H versus measurements made with the zero level at midchest. Methods and Results Using two-dimensional echocardiography, we determined H in the LVs of seven normal patients (five male, two female; age, 49±9 years) undergoing routine cardiac catheterization. H was determined from a left parasternal short-axis view and calculated as the average distance between end diastole and end systole of the endocardium of the uppermost segment of the LV anterior wall below the fourth or fifth intercostal space of the left sternal border on the anterior surface of the chest wall, with the patient in the supine position. A micromanometer/fluid-filled lumen catheter was then positioned in the LV, and we compared the micromanometer LV minimum pressure (LVP min ) obtained when the reference fluid-filled transducer was aligned at midchest with the LVP min obtained when the reference fluid-filled transducer was aligned at H. LVP min referenced to a midchest fluid-filled external transducer was measured as 5.1±1.6 mm Hg (range, 2.4 to 7.2 mm Hg) versus −0.6±0.6 mm Hg (range, −1.6 to 0.4 mm Hg) when referenced to H ( P <.001). A significant linear relation was found to exist between patient anterior-posterior chest diameter and the magnitude of hydrostatic pressure influences related to pressure referenced at midchest ( r =.88; P <.01). Conclusions External fluid-filled transducers should be used with the goal of removing hydrostatic pressure and other influences so that the presence of subatmospheric pressure during diastole in any of the cardiac chambers is accurately measured. To achieve this goal, intracardiac pressure should be referenced to an external fluid-filled transducer aligned with the uppermost blood level in the chamber in which pressure is to be measured. The current practice of referencing the zero level of LV diastolic pressure to an external fluid-filled transducer positioned at the midchest level results in systematic overestimation due to hydrostatic effects and produces physiologically significant error in the measurement of diastolic intracardiac pressure.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference23 articles.

1. Shintani H Glantz SA. The left ventricular diastolic pressure volume relation relaxation and filling. In: Gaasch WH Lewinter MM eds. Left Ventricular Diastolic Dysfunction and Heart Failure . Philadelphia Pa: Lea & Febiger; 1994:57-88.

2. Yellin EL Nikolic SD. Diastolic suction and the dynamics of left ventricular filling. In: Gaasch WH Lewinter MM eds. Left Ventricular Diastolic Dysfunction and Heart Failure . Philadelphia Pa: Lea & Febiger; 1994:89-102.

3. Courtois M Ludbrook PA. Intraventricular pressure transients during relaxation and filling. In: Gaasch WH Lewinter MM eds. Left Ventricular Diastolic Dysfunction and Heart Failure . Philadelphia Pa: Lea & Febiger; 1994:150-166.

4. Udelson JE Bonow RO. Radionuclide angiographic evaluation of left ventricular diastolic function. In: Gaasch WH Lewinter MM eds. Left Ventricular Diastolic Dysfunction and Heart Failure . Philadelphia Pa: Lea & Febiger; 1994:167-191.

5. Zile MR Nishimura RA Gaasch WH. Hemodynamic loads and left ventricular diastolic function: factors affecting the indexes of isovolumetric and auxotonic relaxation. In: Gaasch WH Lewinter MM eds. Left Ventricular Diastolic Dysfunction and Heart Failure . Philadelphia Pa: Lea & Febiger; 1994:219-242.

Cited by 54 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3