Improved Procedural Results of Coronary Angioplasty With Intravascular Ultrasound–Guided Balloon Sizing

Author:

Stone Gregg W.1,Hodgson John M.1,St Goar Frederick G.1,Frey Axel1,Mudra Harald1,Sheehan Helen1,Linnemeier Thomas J.1

Affiliation:

1. From the Cardiovascular Institute, El Camino Hospital, Mountain View, CA (G.W.S., F.G.S.G.); Case Western Reserve University, Cleveland, Ohio (J.M.H., H.S.); Herz Zentrum, Bad Krozingen, Germany (A.F.); Klinikum Innenstadt, University of Munich, Germany (H.M.); and St Vincent’s Hospital, Indianapolis, Ind (T.J.L.).

Abstract

Background Indiscriminate use of balloons larger than the angiographic reference segment lumen results in high rates of ischemic complications after percutaneous transluminal coronary angioplasty (PTCA). We hypothesized that angiographically unsuspected atheromatous remodeling with vessel expansion (the Glagov phenomenon) at and adjacent to PTCA target lesions would safely accommodate oversized balloons in selected patients undergoing PTCA with intravascular ultrasound (IVUS) guidance. Methods and Results After angiographically guided PTCA of 104 lesions in 102 patients, IVUS was performed, and if atheromatous remodeling was present, PTCA was repeated with larger balloons sized halfway between the lumen and external elastic membrane. Plaque occupied a mean of 51±15% of the angiographically “normal” reference segments. Further balloon upsizing by 0.25 to 1.25 mm was therefore performed in 76 lesions (73%), increasing the nominal balloon-to-artery ratio from 1.12±0.15 after standard PTCA to 1.30±0.17 after IVUS-guided PTCA ( P <.0001). As a result, the angiographic minimal luminal diameter further increased from 1.95±0.49 to 2.21±0.47 mm, the % diameter stenosis fell from 28±15% to 18±14%, and the IVUS lumen area rose from 3.16±1.04 to 4.52±1.14 mm 2 (all P <.0001). The incidence of angiographic dissection was not increased after IVUS-guided balloon upsizing (37% versus 40%, P =.67), and major complications occurred in only 2 patients (1.9%). Conclusions The demonstration by IVUS of atheromatous remodeling permits the safe use of balloons traditionally considered oversized, resulting in significantly improved luminal dimensions without increased rates of dissection or ischemic complications.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 138 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3