Accurate Three-Dimensional Reconstruction of Intravascular Ultrasound Data

Author:

Evans James L.1,Ng Kok-Hwee1,Wiet Stephen G.1,Vonesh Michael J.1,Burns William B.1,Radvany Martin G.1,Kane Bonnie J.1,Davidson Charles J.1,Roth Sanford I.1,Kramer Barry L.1,Meyers Sheridan N.1,McPherson David D.1

Affiliation:

1. From the Departments of Medicine and Pathology, Northwestern University Medical School, Chicago, Ill.

Abstract

Background The geometrical accuracy of conventional three-dimensional (3D) reconstruction methods for intravascular ultrasound (IVUS) data (coronary and peripheral) is hampered by the inability to register spatial image orientation and by respiratory and cardiac motion. The objective of this work was the development of improved IVUS reconstruction techniques. Methods and Results We developed a 3D position registration method that identifies the spatial coordinates of an in situ IVUS catheter by use of simultaneous ECG-gated biplane digital cinefluoroscopy. To minimize distortion, coordinates underwent pincushion correction and were referenced to a standardized calibration cube. Gated IVUS data were acquired digitally, and the spatial locations of the imaging planes were matched to their corresponding coordinates. Image points were then transformed relative to their respective 3D coordinates, rendered in binary voxel format, resliced, and displayed on an image-processing workstation for off-line analysis. The method was tested by use of phantoms (straight tube, 360° circle, 240° spiral) and an in vitro coronary artery model. In vivo feasibility was assessed in patients who underwent routine interventional coronary procedures accompanied by IVUS evaluation. Actual versus calculated point locations were within 1.0±0.3 mm of each other (n=39). Calculated phantom volumes were within 4% of actual volumes. Phantom 3D reconstruction appropriately demonstrated complex morphology. Initial patient evaluation demonstrated method feasibility as well as errors if respiratory and ECG gating were not used. Conclusions These preliminary data support the use of this new method of 3D reconstruction of vascular structures with use of combined vascular ultrasound data and simultaneous ECG-gated biplane cinefluoroscopy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 79 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3