Energetically Optimal Left Ventricular Pressure for the Failing Human Heart

Author:

Asanoi Hidetsugu1,Kameyama Tomoki1,Ishizaka Shinji1,Nozawa Takashi1,Inoue Hiroshi1

Affiliation:

1. From the Second Department of Internal Medicine, Toyama Medical and Pharmaceutical University, Toyama, Japan.

Abstract

Background An energy-starved failing heart would benefit from more effective transfer of the mechanical energy of ventricular contraction to blood propulsion. However, the energetically optimal loading conditions for the failing heart are difficult to establish. In the present study, we analyzed the optimal left ventricular pressure to achieve maximal mechanical efficiency of the failing heart in humans. Methods and Results We determined the relation between left ventricular pressure-volume area and myocardial oxygen consumption per beat (V o 2 ), stroke work, and mechanical efficiency (stroke work/V o 2 ) in 13 patients with different contractile states. We also calculated the optimal end-systolic pressure that would theoretically maximize mechanical efficiency for a given end-diastolic volume and contractility. Left ventricular pressure-volume loops were constructed by plotting the instantaneous left ventricular pressure against the left ventricular volume at baseline and during pressure loading. The contractile properties of the ventricle were defined by the slope of the end-systolic pressure-volume relation. In patients with less compromised ventricular function, the operating end-systolic pressure was close to the optimal pressure, achieving nearly maximal mechanical efficiency. As the heart deteriorated, however, the optimal end-systolic pressure became significantly lower than normal, whereas the actual pressure remained within the normal range. This discrepancy resulted in worsening of ventriculoarterial coupling and decreased mechanical efficiency compared with theoretically maximal efficiency. Conclusions Homeostatic mechanisms to maintain arterial blood pressure within the normal range cause the failing heart to deviate from energetically optimal conditions.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference43 articles.

Cited by 23 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3