A Prospective Randomized Comparison in Humans of Biphasic Waveform 60-μF and 120-μF Capacitance Pulses Using A Unipolar Defibrillation System

Author:

Bardy Gust H.1,Poole Jeanne E.1,Kudenchuk Peter J.1,Dolack G. Lee1,Mehra Rahul1,DeGroot Paul1,Raitt Merritt H.1,Jones Gregory K.1,Johnson George1

Affiliation:

1. From the Department of Medicine, University of Washington (Seattle).

Abstract

BackgroundImproving unipolar implantable cardioverter-defibrillator (ICD) effectiveness has favorable implications for ICD safety, efficacy, and size. Advances in defibrillation efficacy would accelerate ICD ease of use by decreasing device size and by minimizing morbidity and mortality related to an improved defibrillation safety margin. The specific purpose of the present study was to determine whether unipolar defibrillation efficacy could be improved further in humans by lowering biphasic waveform capacitance.Methods and ResultsWe prospectively and randomly compared the defibrillation efficacy of a 60-μF and a 120-μF capacitance asymmetrical 65% tilt biphasic waveform using a unipolar defibrillation system in 38 consecutive cardiac arrest survivors before implantation of a presently available standard transvenous defibrillation system. The right ventricular defibrillation electrode had a 5-cm coil located on a 10.5F lead and was used as the anode. The system cathode was the electrically active 108-cm2surface area shell (or “can”) of a prototype titanium alloy pulse generator placed in a left infraclavicular pocket. The defibrillation pulse was derived from either a 60-μF or a 120-μF capacitance and was delivered from RV → CAN. Defibrillation threshold (DFT) stored energy, delivered energy, leading-edge voltage and current, pulse resistance, and pulse width were measured for both capacitances examined. The 60-μF capacitance biphasic pulse resulted in a stored-energy DFT of 8.5±4.1 J and a delivered-energy DFT of 8.4±4.0 J. In 34 of 38 patients (89%), the stored-energy DFT was <15 J. Leading-edge voltage at the DFT was 517±128 V. Mean pulse impedance for the 60-μF waveform was 60.6±7.1 Ω. The 120-μF capacitance biphasic pulse resulted in a stored-energy DFT of 10.1±7.4 J and a delivered-energy DFT of 10.0±7.2 J (P=.13 and .13, respectively). In 28 of 38 patients (74%), the stored-energy DFT was <15 J (P=.052). Leading-edge voltage at the DFT with the 120-μF capacitance pulse was 386±142 (P<.00001). Mean pulse impedance for the 120-μF waveform was 60.7±7.0 Ω (P=.80).ConclusionsThe results of the present study suggest that a relatively small capacitance, 60 μF, can be used for unipolar defibrillation systems without compromising defibrillation energy requirements compared with more typical ICD capacitance values, but this will require a higher circuit voltage. The use of lower capacitance also provides a modest increase in the percent of patients who have very low energy defibrillation requirements, an important issue should maximum ICD energy be decreased from the present level of 34 J. Such a move to smaller output devices could allow significant decreases in device size, a necessary feature of making cardioverter-defibrillator implantation comparable to that of standard pacemaker surgery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 33 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3