Abstract

Background Three-dimensional echocardiography is a promising technique for calculation of left ventricular ejection fraction, because it allows its measurement without geometric assumptions. However, few data exist that study its reproducibility and accuracy in patients. Methods and Results Twenty-five patients underwent radionuclide angiography and three-dimensional echocardiography that used the rotational technique (2° interval and ECG and respiratory gating). Left ventricular volume and ejection fraction were calculated by use of Simpson's rule at a slice thickness of 3 mm. Analyses were performed to define the largest slice thickness required for accurate calculation of left ventricular volume and ejection fraction. Three-dimensional echocardiography showed excellent correlation with radionuclide angiography for calculation of left ventricular ejection fraction (mean±SD, 38.9±19.8 and 38.5±18.0, respectively; r =.99); their mean difference was not significant (0.03±0.17; P =.3), and they had a close limit of agreement (−0.385, 0.315). Intraobserver variability for radionuclide angiography and three-dimensional echocardiography was 4.2% and 2.6%, respectively, whereas interobserver variability was 6.2% and 5.3%, respectively. There was no significant difference between left ventricular volume and ejection fraction calculated at a slice thickness of 3 mm and that calculated at different slice thicknesses up to 24 mm. However, the standard deviation of the mean difference showed a stepwise increase, particularly at thicknesses >15 mm. At a slice thickness of 15 mm, the probability of three-dimensional echocardiography to detect ≥6% difference in ejection fraction was 80%. Conclusions Three-dimensional echocardiography has excellent correlation with radionuclide angiography for calculation of left ventricular ejection fraction in patients and has an observer variability similar to that of radionuclide angiography. We recommend the use of a 15-mm-thick slice for accurate and rapid measurement of left ventricular volume and ejection fraction.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3