Quantification of collateral blood flow in coarctation of the aorta by velocity encoded cine magnetic resonance imaging.

Author:

Steffens J C1,Bourne M W1,Sakuma H1,O'Sullivan M1,Higgins C B1

Affiliation:

1. Department of Radiology, University of California, San Francisco 94143-0628.

Abstract

BACKGROUND Knowledge about the volume of collateral flow provides insight into the severity of coarctation of the aorta and may be critical in planning the operative approach. There is currently no method for the quantification of collateral flow in coarctation of the aorta. In this study, we applied velocity encoded cine magnetic resonance imaging (VENC-MR) to establish the flow pattern and volume of collateral flow in the descending thoracic aorta in normal subjects and patients with coarctation, introducing a new possibility to quantify the severity of the coarctation by determining the amount of collateral flow. METHODS AND RESULTS VENC-MR was used to measure flow in the proximal and distal descending thoracic aorta in 10 normal subjects. In 23 patients with coarctation, flow was measured near the coarctation site and above the diaphragm. Patients were divided into a group with moderate to severe coarctation and a group with mild coarctation on the basis of clinical gradient between upper and lower extremities and the estimation of the gradient across the coarctation by Doppler echocardiography. The gradient across the coarctation and the degree of anatomic narrowing were also assessed by MR imaging. In normal volunteers, VENC-MR showed a 7 +/- 6% decrease in total flow, from proximal to distal aorta. The interobserver reproducibility was 3.9% to 4.9% (mean, 4.4%). In patients with moderate to severe coarctation, VENC-MR demonstrated an 83 +/- 50% increase in total flow from proximal to distal aorta, yielding a significant change compared with normal subjects (P < .01). Patients with mild coarctation showed a normal flow pattern and no significant change in total flow. There was a significant relation between the amount of flow increase in the distal aorta and the reduction in luminal diameter at the coarctation site (r = .94) as well as the clinical gradient (r = .84). CONCLUSIONS This study shows the normal flow pattern in the descending thoracic aorta and its reversal in coarctation due to collateral flow. Thus, VENC-MR can measure collateral flow in coarctation and serves as a unique method for providing this important measurement of the severity of coarctation of the aorta.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Reference31 articles.

1. Silver EN. Heart Disease. 2nd ed. New York NY: Macmillan Publishing Co; 1987;765.

2. Kirklin JW Boyes BH. Cardiac Surgery. 2nd ed. New York NY: Churchill Livingstone; 1993;1267.

3. Braunwald E. Heart Disease: A Textbook of Cardiovascular Medicine. 3rd ed. Philadelphia Pa: WB Saunders Co; 1988: 994-997.

4. MR Imaging of the Thoracic Aorta in Marfan Patients

5. Magnetic resonance imaging of thoracic aortic aneurysms: comparison with other imaging methods

Cited by 186 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3