Reconstruction of Brachial Artery Pressure From Noninvasive Finger Pressure Measurements

Author:

Bos Willem Jan W.1,van Goudoever Jeroen1,van Montfrans Gert A.1,van den Meiracker Anton H.1,Wesseling Karel H.1

Affiliation:

1. the Department of Internal Medicine I (W.J.W.B., A.H.v.d.M.), University Hospital Rotterdam, Dijkzigt, Rotterdam, and TNO–Biomedical Instrumentation (J.v.G., K.H.W.) and Department of Internal Medicine (W.J.W.B., G.A.v.M.), Academic Medical Center, Amsterdam, The Netherlands.

Abstract

Background Pulse wave distortions, mainly caused by reflections, and pressure gradients, caused by flow in the resistive vascular tree, may cause differences between finger and brachial artery pressures. These differences may limit the use of finger pressure measurements. We investigated whether brachial artery pressure waves could be reconstructed from finger pressure measurements by correcting for the pressure gradient in addition to correction for pulse wave distortion with a previously described filter. Methods and Results Finger artery pressure (with Finapres), intra-arterial brachial artery pressure (BAP), Riva-Rocci/Korotkoff (RRK), oscillometric, and return-to-flow (RTF) measurements were simultaneously performed in 57 healthy elderly subjects and patients with vascular disease and/or hypertension. A generalized waveform filter was used to correct for pulse wave distortions. Correction equations for the pressure gradient, based on finger pressure, RRK, RTF, or oscillometric measurements, were obtained in 28 randomly selected subjects and tested in 29. Before reconstruction, Finapres underestimated mean and diastolic BAP (finger pressure minus BAP: systolic, −3.2±16.9 mm Hg; mean, −13.0±10.5 mm Hg; diastolic, −8.4±9.0 mm Hg [mean±SD]). After filtering, reconstructed BAP waves were similar to actual BAP in shape but not in pressure level. Optimal correction for the pressure gradient with an equation based on RTF measurements reduced the pressure differences to meet American Association for the Advancement of Medical Instrumentation criteria (reconstructed finger pressure minus BAP: systolic, 3.7±7.0 mm Hg; mean, 0.7±4.6 mm Hg; and diastolic, 1.0±4.9 mm Hg). Conclusions BAP waves can be reconstructed from noninvasive finger pressure registrations when finger pressure waves are corrected for pulse wave distortion and individual pressure gradients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3