Robust Adenoviral and Adeno-Associated Viral Gene Transfer to the In Vivo Murine Heart

Author:

Champion Hunter C.1,Georgakopoulos Dimitrios1,Haldar Saptarsi1,Wang Lili1,Wang Yibin1,Kass David A.1

Affiliation:

1. From the Division of Cardiology, Department of Medicine (H.C.C., D.G., S.H., D.A.K.), Johns Hopkins Hospital, Baltimore, Md; Institute for Human Gene Therapy (L.W.), University of Pennsylvania, Philadelphia, Pa; and University of Maryland School of Medicine (Y.W.), Baltimore, Md.

Abstract

Background— Viral gene transfer to the whole heart in vivo has been achieved in several mammalian species but remained difficult to accomplish in murine hearts. We postulated that a key impediment derives from the use of proximal aortic occlusion during virus injection, because this eliminates coronary perfusion gradients in mice as aortic root and left ventricle pressures equalize. Methods and Results— Pressure-volume analysis confirmed these mechanics. In contrast, descending aortic occlusion with whole-body cooling (20°C) preserved transmyocardial perfusion gradients and allowed for sustained (>10-minute) dwell times in an upper-body perfusion circuit. This approach yielded robust cardiac transfection with adenovirus (AdV) and adeno-associated virus (AAV) injected into the left ventricle cavity or more simply via a central vein. Cardio-specific expression was achieved with a myocyte-specific promotor. Optimal AdV transfection required 9-minute aortic occlusion, versus 5-minute occlusion for AAV. Using this method, we examined the in vivo function of phospholamban (PLB) by stably transfecting PLB-null mice with AAV encoding PLB (AAV PLB ). AAV PLB restored PLB protein to near control levels that colocalized with SERCA2A in cardiomyocytes. At baseline, PLB-null hearts exhibited enhanced systolic and diastolic function, but frequency-dependent reserve was blunted versus wild-type controls. These properties, particularly the frequency response, returned toward control 3 months after AAV PLB transfection. Conclusions— The new simplified approach for murine whole-heart viral transfection should assist molecular physiology studies.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3