Endoscopic Exposure and Stabilization of Posterior and Inferior Branches Using the Endo-Starfish Cardiac Positioner and the Endo-Octopus Stabilizer for Closed-Chest Beating Heart Multivessel CABG: Hemodynamic Changes in the Pig

Author:

Gründeman Paul F.1,Budde Ricardo1,Beck Hendricus Mansvelt1,van Boven Wim-Jan1,Borst Cornelius1

Affiliation:

1. From the *Department of Cardiology, University Medical Center Utrecht, Utrecht, the Netherlands; and the †Department of Cardiothoracic Surgery, St. Antonius Hospital, Nieuwegein, the Netherlands.

Abstract

Background— Closed-chest, off-pump, multivessel CABG requires modified instruments to expose and stabilize posterior and inferior coronary branches. Using three new prototype devices, we explored the feasibility of endoscopic bypass grafting on these branches and assessed cardiac function during cardiac displacement. Methods— Eight pigs (75 to 85 kg) were instrumented for hemodynamics and paced at 80 to 100 bpm. After closure of the sternotomy wound, the Da Vinci endoscope was inserted subxiphoidally. A sternal hook was used to hoist the sternum ventrally by 5 cm. The articulating EndoStarfish cardiac positioner was placed through a trocar (Ø12 mm). The positioner was fixed to the apex using −400 mm Hg suction and the heart was displaced anteriorly to 90 degrees. In 12 other pigs (75 to 85 kg), both internal mammary arteries (IMA) were harvested and the sternal wound was closed. Five trocar ports were placed for instrumentation (Ø12 mm, two in left chest, two in right chest, and one subxiphoidally). For coronary stabilization, a novel deployable EndoOctopus cardiac stabilizer was employed (suction −400 mm Hg). The Da Vinci robot-telemanipulator system was used for endoscopic grafting of the left and right IMA on posterior and inferior branches (16 anastomoses). Results— When circumflex arteries were fully exposed and accessible for coronary surgery, stroke volume decreased by 18%±3 versus baseline ( P =0.02) and mean arterial pressure decreased by 27%±6 ( P =0.001). Additional 10 degrees Trendelenburg head-down positioning normalized stroke volume and arterial pressure. In the displaced heart, obtuse marginal branches (OM) and the ramus descending posterior (RDP) of the right coronary artery became fully exposed with a mean arterial pressure >70 mm Hg during grafting. No accidental detachment occurred. Coronary target motion was restrained to approximately 1×1 mm. In two test cases, five sham distal anastomoses were created (grafts sewn to epicardium, left IMA to OM2 jump to OM3, right IMA to RDP, and composite graft from left IMA jump to diagonal branch). In 10 animals, 16 successfully completed anastomoses to RPD and OM branches of Ø1.75 to 2.5 mm required 25 to 60 minutes each to construct. At sacrifice, all anastomoses were patent. Conclusion— In the closed-chest pig in Trendelenburg position and during lifting of the sternum, the EndoStarfish and EndoOctopus enabled IMA grafting of posterior and inferior branches on the beating heart without mean arterial pressure dropping below 70 mm Hg.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3