Evaluation of Venous and Arterial Conduit Patency by 16-Slice Spiral Computed Tomography

Author:

Martuscelli E.1,Romagnoli A.1,D’Eliseo A.1,Tomassini M.1,Razzini C.1,Sperandio M.1,Simonetti G.1,Romeo F.1,Mehta J.L.1

Affiliation:

1. From the Department of Cardiology (E.M., A.D., C.R., F.R.) and Department of Diagnostic Imaging (A.R., M.T., M.S., G.S.), Tor Vergata University, Rome, Italy, and Division of Cardiovascular Medicine (J.L.M.), University of Arkansas for Medical Sciences, Little Rock, Ark.

Abstract

Background— Computed tomography has been shown to be useful in the evaluation of aortocoronary bypass grafts (CABG). This is the first prospective study to evaluate the accuracy of a new-generation scanner in the detection of patency and significant stenoses (>50% decrease in diameter) of venous and arterial grafts in patients with previous CABG. Methods and Results— In 96 patients (80 males, mean age 62 years) with previous CABG, a multislice computed tomography (MSCT) scan was performed (collimation 16×0.625 mm). Patients with atrial fibrillation, renal failure, severe respiratory disease, severe heart failure, heart rate >70 bpm despite therapy, or unstable angina were excluded. A total of 285 conduits implanted on the native coronary arteries at the time of CABG were evaluated. MSCT data were analyzed by 2 independent radiologists and compared with the results of conventional angiography. Three patients were excluded from analysis. All conduits were judged evaluable in 84 patients. Among these patients, MSCT correctly diagnosed 54 occluded grafts and 4 significant stenoses on the body of the grafts. Of the 17 significant anastomotic lesions, MSCT correctly diagnosed 15. For these 84 patients, diagnostic accuracy was 99%, sensitivity was 97%, and specificity was 100%. When all 93 patients were considered, the sensitivity of MSCT in diagnosing significant stenoses was 96%. Conclusions— MSCT with the new-generation scanner allows for accurate assessment of venous and arterial conduits in patients with previous CABG with a high degree of sensitivity and specificity. Exclusion criteria and radiation exposure remain limitations of the method.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 146 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3