Four-Year Angiographic and Intravascular Ultrasound Follow-Up of Patients Treated With Sirolimus-Eluting Stents

Author:

Sousa J. Eduardo1,Costa Marco A.1,Abizaid Alexandre1,Feres Fausto1,Seixas Ana C.1,Tanajura Luiz F.1,Mattos Luiz A.1,Falotico Robert1,Jaeger Judith1,Popma Jeffrey J.1,Serruys Patrick W.1,Sousa Amanda G.M.R.1

Affiliation:

1. From Institute Dante Pazzanese of Cardiology (J.E.S., A.A., F.F., A.C.S., L.F.T., L.A.M., A.G.M.R.S.), São Paulo, Brazil; University of Florida, Shands-Jacksonville (M.A.C.), Jacksonville, Fla; Cordis, a Johnson & Johnson Company (R.F., J.J.), Warren, NJ; Brigham and Women’s Hospital (J.J.P.), Boston, Mass; and Thoraxcenter, Dijkzigt University Hospital (P.W.S.), Rotterdam, the Netherlands.

Abstract

Background— Despite the proven superiority of sirolimus-eluting stents (SESs) compared with bare stents in the first year after implantation, long-term outcomes of patients treated with these novel devices remain unknown. Our goal was to evaluate the clinical, angiographic, and intravascular ultrasound (IVUS) outcomes of patients treated with SESs 4 years after implantation. Methods and Results— The study included 30 patients treated with sirolimus-eluting Bx Velocity stenting (slow release [SR; n=15] and fast release [FR; n=15]). Twenty-six patients underwent 4-year angiographic and IVUS follow-up and had matched assessments at all time points (index and 4-, 12-, 24-, and 48-month follow-up). One death occurred during the study period in a patient with a patent SES. There were no target-vessel revascularizations or thromboses between 2- and 4-year follow-up examinations. There was no stent thrombosis, target-lesion revascularization, death, or myocardial infarction in the SR group up to 4 years. Cumulative event-free survival rate was 87% for the total population (80% in the FR group and 93% in the SR group). In-stent late loss was slightly greater in the FR group (0.41±0.49 mm) than the SR group (0.09±0.23) after 4 years. One patient in the FR group had a 52% in-stent restenosis lesion. Percent neointimal hyperplasia volume, as detected by IVUS, remained minimal after 4 years (FR=9.1% and SR=5.7%). Conclusions— This study confirms the longevity of the optimal outcomes observed in patients treated with sirolimus-eluting Bx Velocity stents 4 years after implantation. In-stent lumen dimensions remained essentially unchanged at 4-year follow-up, particularly in the population treated with the currently available SES (SR formulation).

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 142 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3