Results of Prevention of REStenosis with Tranilast and its Outcomes (PRESTO) Trial

Author:

Holmes David R.1,Savage Michael1,LaBlanche J.-M.1,Grip Lars1,Serruys P.W.1,Fitzgerald Peter1,Fischman David1,Goldberg Sheldon1,Brinker Jeffrey A.1,Zeiher A.M.1,Shapiro Leonard M.1,Willerson James1,Davis Barry R.1,Ferguson James J.1,Popma Jeffrey1,King Spencer B.1,Lincoff A. Michael1,Tcheng James E.1,Chan Robert1,Granett Jeffrey R.1,Poland Marcia1

Affiliation:

1. From the Mayo Clinic (D.R.H.), Rochester, Minn; Jefferson University Hospital (M.S.), Philadelphia, Pa; Hospital Cardiologique (J.-M.L.), Lille, France; Gothenburg University (L.G.), Gothenburg, Sweden; Heartcentre (P.W.S.), Rotterdam, the Netherlands; Stanford University (P.F.), Stanford, Calif; Jefferson University Angiography Core Lab (D.F.), Philadelphia, Pa; Cooper Hospital University Medical Center (S.G.), Camden, NJ; Johns Hopkins University Hospital (J.A.B.), Baltimore, Md; Johann-Wolfgang...

Abstract

Background— Restenosis after percutaneous coronary intervention (PCI) is a major problem affecting 15% to 30% of patients after stent placement. No oral agent has shown a beneficial effect on restenosis or on associated major adverse cardiovascular events. In limited trials, the oral agent tranilast has been shown to decrease the frequency of angiographic restenosis after PCI. Methods and Results— In this double-blind, randomized, placebo-controlled trial of tranilast (300 and 450 mg BID for 1 or 3 months), 11 484 patients were enrolled. Enrollment and drug were initiated within 4 hours after successful PCI of at least 1 vessel. The primary end point was the first occurrence of death, myocardial infarction, or ischemia-driven target vessel revascularization within 9 months and was 15.8% in the placebo group and 15.5% to 16.1% in the tranilast groups ( P =0.77 to 0.81). Myocardial infarction was the only component of major adverse cardiovascular events to show some evidence of a reduction with tranilast (450 mg BID for 3 months): 1.1% versus 1.8% with placebo ( P =0.061 for intent-to-treat population). The primary reason for not completing treatment was ≥1 hepatic laboratory test abnormality (11.4% versus 0.2% with placebo, P <0.01). In the angiographic substudy composed of 2018 patients, minimal lumen diameter (MLD) was measured by quantitative coronary angiography. At follow-up, MLD was 1.76±0.77 mm in the placebo group, which was not different from MLD in the tranilast groups (1.72 to 1.78±0.76 to 80 mm, P =0.49 to 0.89). In a subset of these patients (n=1107), intravascular ultrasound was performed at follow-up. Plaque volume was not different between the placebo and tranilast groups (39.3 versus 37.5 to 46.1 mm 3 , respectively; P =0.16 to 0.72). Conclusions— Tranilast does not improve the quantitative measures of restenosis (angiographic and intravascular ultrasound) or its clinical sequelae.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3